Datasheet

Switching Characteristics
Operating Characteristics
SN74LVC125A-Q1
SCAS762B FEBRUARY 2004 REVISED APRIL 2008 ..................................................................................................................................................
www.ti.com
over recommended operating free-air temperature range (unless otherwise noted) (see Figure 1 )
T
A
= 25 ° C 40 ° C to 125 ° C
FROM TO
PARAMETER V
CC
UNIT
(INPUT) (OUTPUT)
MIN TYP MAX MIN MAX
2.7 V 1 3 5.3 1 7
t
pd
A Y ns
3.3 V ± 0.3 V 1 2.5 4.6 1 6
2.7 V 1 3.3 6.4 1 8.5
t
en
OE Y ns
3.3 V ± 0.3 V 1 2.4 5.2 1 7
2.7 V 1 2.5 4.8 1 6.5
t
dis
OE Y ns
3.3 V ± 0.3 V 1 2.4 4.4 1 6
t
sk(o)
3.3 V ± 0.3 V 1.5 ns
T
A
= 25 ° C
TEST
PARAMETER V
CC
TYP UNIT
CONDITIONS
C
pd
Power dissipation capacitance per gate f = 10 MHz 3.3 V 15 pF
4 Submit Documentation Feedback Copyright © 2004 2008, Texas Instruments Incorporated
Product Folder Link(s): SN74LVC125A-Q1