Datasheet

www.ti.com
Absolute Maximum Ratings
(1)
Recommended Operating Conditions
(1)
SN74LVC112A
DUAL NEGATIVE-EDGE-TRIGGERED J-K FLIP-FLOP
WITH CLEAR AND PRESET
SCAS289L JANUARY 1993 REVISED AUGUST 2005
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
CC
Supply voltage range –0.5 6.5 V
V
I
Input voltage range
(2)
–0.5 6.5 V
V
O
Output voltage range
(2) (3)
–0.5 V
CC
+ 0.5 V
I
IK
Input clamp current V
I
< 0 –50 mA
I
OK
Output clamp current V
O
< 0 –50 mA
I
O
Continuous output current ± 50 mA
Continuous current through V
CC
or GND ± 100 mA
D package 73
DB package 82
θ
JA
Package thermal impedance
(4)
DGV package 120 ° C/W
NS package 64
PW package 108
T
stg
Storage temperature range –65 150 ° C
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) The input and output negative-voltage ratings may be exceeded if the input and output current ratings are observed.
(3) The value of V
CC
is provided in the recommended operating conditions table.
(4) The package thermal impedance is calculated in accordance with JESD 51-7.
MIN MAX UNIT
Operating 1.65 3.6
V
CC
Supply voltage V
Data retention only 1.5
V
CC
= 1.65 V to 1.95 V 0.65 × V
CC
V
IH
High-level input voltage V
CC
= 2.3 V to 2.7 V 1.7 V
V
CC
= 2.7 V to 3.6 V 2
V
CC
= 1.65 V to 1.95 V 0.35 × V
CC
V
IL
Low-level input voltage V
CC
= 2.3 V to 2.7 V 0.7 V
V
CC
= 2.7 V to 3.6 V 0.8
V
I
Input voltage 0 5.5 V
V
O
Output voltage 0 V
CC
V
V
CC
= 1.65 V –4
V
CC
= 2.3 V –8
I
OH
High-level output current mA
V
CC
= 2.7 V –12
V
CC
= 3 V –24
V
CC
= 1.65 V 4
V
CC
= 2.3 V 8
I
OL
Low-level output current mA
V
CC
= 2.7 V 12
V
CC
= 3 V 24
t/ v Input transition rise or fall rate 10 ns/V
T
A
Operating free-air temperature –40 85 ° C
(1) All unused inputs of the device must be held at V
CC
or GND to ensure proper device operation. Refer to the TI application report,
Implications of Slow or Floating CMOS Inputs, literature number SCBA004.
3