Datasheet

www.ti.com
Switching Characteristics
Switching Characteristics
Operating Characteristics
SN54LVC02A, SN74LVC02A
QUADRUPLE 2-INPUT POSITIVE-NOR GATES
SCAS280Q JANUARY 1993 REVISED JULY 2005
over recommended operating free-air temperature range (unless otherwise noted) (see Figure 1 )
SN54LVC02A
FROM TO
PARAMETER V
CC
–55 ° C to 125°C UNIT
(INPUT) (OUTPUT)
MIN MAX
2.7 V 5.4
t
pd
A or B Y ns
3.3 V ± 0.3 V 1 4.4
over recommended operating free-air temperature range (unless otherwise noted) (see Figure 1 )
SN74LVC02A
FROM TO
PARAMETER V
CC
T
A
= 25°C –40 ° C to 85°C –40 ° C to 125°C UNIT
(INPUT) (OUTPUT)
MIN TYP MAX MIN MAX MIN MAX
1.8 V ± 0.15 V 1 3.8 8.4 1 8.9 1 10.4
2.5 V ± 0.2 V 1 2.9 6.9 1 7.4 1 9.5
t
pd
A or B Y ns
2.7 V 1 3 5.2 1 5.4 1 7
3.3 V ± 0.3 V 1 3.6 4.2 1 4.4 1 5.5
t
sk(o)
3.3 V ± 0.3 V 1 1.5 ns
T
A
= 25°C
TEST
PARAMETER V
CC
TYP UNIT
CONDITIONS
1.8 V 7.5
C
pd
Power dissipation capacitance per gate f = 10 MHz 2.5 V 8.5 pF
3.3 V 9.5
5