Datasheet
SCLS589 − AUGUST 2004
7
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
switching characteristics over recommended operating free-air temperature range,
V
CC
= 5 V ± 0.5 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
TO
LOAD
T
A
= 25°C
MIN
MAX
UNIT
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
LOAD
CAPACITANCE
MIN TYP MAX
MIN
MAX
UNIT
f
MAX
C
L
= 15 pF 40
MHz
f
MAX
C
L
= 50 pF 25
MHz
t
pd
RCLK Y 14 1 25
ns
t
pd
CLKA RCOA 16 1 27
ns
t
PLH
CCLR RCOA
C
L
= 15 pF
12 1 20 ns
t
en
GAL, GAU, GBL, GBU Y
C
L
= 15 pF
16 1 28 ns
t
dis
GAL, GAU, GBL, GBU Y 8 1 15 ns
t
pd
RCLK Y 16 1 27
ns
t
pd
CLKA RCOA 17 1 28
ns
t
PLH
CCLR RCOA
C
L
= 50 pF
13 1 21 ns
t
en
GAL, GAU, GBL, GBU Y
C
L
= 50 pF
18 1 30 ns
t
dis
GAL, GAU, GBL, GBU Y 9 1 16 ns
noise characteristics, V
CC
= 5 V, C
L
= 50 pF
PARAMETER
T
A
= 25°C
UNIT
PARAMETER
MIN TYP MAX
UNIT
V
OL(P)
Quiet output, maximum dynamic V
OL
0.7 V
V
OL(V)
Quiet output, minimum dynamic V
OL
−0.75 V
V
OH(V)
Quiet output, minimum dynamic V
OH
4.4 V
operating characteristics, V
CC
= 5 V, T
A
= 25°C
PARAMETER TEST CONDITIONS TYP UNIT
C
pd
Power dissipation capacitance C
L
= No load, CCLK = 10 MHz, RCLK = 1 MHz 56 pF