ELECTRICAL CHARACTERISTICS
over operating free-air temperature range (unless otherwise noted)
SN54LV4052A
T
A
= 25°C SN74LV4052A
(1)
PARAMETER TEST CONDITIONS V
CC
UNIT
MIN TYP MAX MIN MAX MIN MAX
I
T
= 2 mA, , 2.3 V 43 180 225 225
On-state switch V
I
= V
CC
or GND,
3 V 34 150 190 190
r
on
Ω
resistance V
INH
= V
IL
4.5 V 25 75 100 100
(see Figure 1)
2.3 V 133 500 600 600
I
T
= 2 mA,
r
on(p)
Peak on-state resistance V
I
= V
CC
to GND, 3 V 63 180 225 225 Ω
V
INH
= V
IL
4.5 V 35 100 125 125
2.3 V 1.5 30 40 40
Difference in on-state I
T
= 2 mA,
Δr
on
resistance between V
I
= V
CC
to GND, 3 V 1.1 20 30 30 Ω
switches V
INH
= V
IL
4.5 V 0.7 15 20 20
0 to
I
I
Control input current V
I
= 5.5 V or GND ±0.1 ±1 ±1 µA
5.5 V
V
I
= V
CC
and V
O
= GND,
Off-state switch leakage or
I
S(off)
5.5 V ±0.1 ±1 ±1 µA
current V
I
= GND and V
O
= V
CC
,
V
INH
= V
IH
(see Figure 2)
V
I
= V
CC
or GND,
On-state switch leakage
I
S(on)
V
INH
= V
IL
5.5 V ±0.1 ±1 ±1 µA
current
(see Figure 3)
I
CC
Supply current V
I
= V
CC
or GND 5.5 V 20 20 µA
C
IC
Control input capacitance f = 10 MHz 3.3 V 2.1 pF
Common terminal
C
IS
3.3 V 13.1 pF
capacitance
Switch terminal
C
OS
3.3 V 5.6 pF
capacitance
C
F
Feedthrough capacitance 3.3 V 0.5 pF
(1) Product Preview
4 Submit Documentation Feedback Copyright © 1999–2012, Texas Instruments Incorporated
Product Folder Links: SN54LV4052A SN74LV4052A