Datasheet

SN54LV163A, SN74LV163A
4-BIT SYNCHRONOUS BINARY COUNTERS
SCLS405F − APRIL 1998 − REVISED APRIL 2005
8
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
timing requirements over recommended operating free-air temperature range,
V
CC
= 2.5 V ± 0.2 V (unless otherwise noted) (see Figure 1)
T
A
= 25°C SN54LV163A SN74LV163A
UNIT
MIN MAX MIN MAX MIN MAX
UNIT
t
w
Pulse duration, CLK high or low 7 7 7 ns
CLR 6 6 6
t
Set p time before CLK
Data (A, B, C, and D) 7.5 8.5 8.5
ns
t
su
Setup time before CLK
ENP, ENT 9.5 11 11
ns
LOAD low 10 11.5 11.5
t
h
Hold time, all synchronous inputs after CLK 1.5 1.5 1.5 ns
timing requirements over recommended operating free-air temperature range,
V
CC
= 3.3 V ± 0.3 V (unless otherwise noted) (see Figure 1)
T
A
= 25°C SN54LV163A SN74LV163A
UNIT
MIN MAX MIN MAX MIN MAX
UNIT
t
w
Pulse duration, CLK high or low 5 5 5 ns
CLR 4 4 4
t
S t ti b f CLK
Data (A, B, C, and D) 5.5 6.5 6.5
ns
t
su
Setup time before CLK
ENP, ENT
7.5 9 9
ns
LOAD low 8 9.5 9.5
t
h
Hold time, all synchronous inputs after CLK 1 1 1 ns
timing requirements over recommended operating free-air temperature range, V
CC
= 5 V ± 0.5 V
(unless otherwise noted) (see Figure 1)
T
A
= 25°C SN54LV163A SN74LV163A
UNIT
MIN MAX MIN MAX MIN MAX
UNIT
t
w
Pulse duration, CLK high or low 5 5 5 ns
CLR 3.5 3.5 3.5
t
S t ti b f CLK
Data (A, B, C, and D) 4.5 4.5 4.5
ns
t
su
Setup time before CLK
ENP, ENT
5 6 6
ns
LOAD low 5 6 6
t
h
Hold time, all synchronous inputs after CLK 1 1 1 ns
PRODUCT PREVIEW information concerns products in the formative or
design phase of development. Characteristic data and other
specifications are design goals. Texas Instruments reserves the right to
change or discontinue these products without notice.