Absolute Maximum Ratings
(1)
SN54LV138A, SN74LV138A
3-LINE TO 8-LINE DECODERS/DEMULTIPLEXERS
SCLS395L – APRIL 1998 – REVISED AUGUST 2005
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
CC
Supply voltage range –0.5 7 V
V
I
Input voltage range
(2)
–0.5 7 V
V
O
Voltage range applied to any output in the high-impedance or power-off state
(2)
–0.5 7 V
V
O
Output voltage range
(2) (3)
–0.5 V
CC
+ 0.5 V
I
IK
Input clamp current V
I
< 0 –20 mA
I
OK
Output clamp current V
O
< 0 –50 mA
I
O
Continuous output current V
O
= 0 to V
CC
± 25 mA
Continuous current through V
CC
or GND ± 50 mA
D package
(4)
73
DB package
(4)
82
DGV package
(4)
120
θ
JA
Package thermal impedance ° C/W
NS package
(4)
64
PW package
(4)
108
RGY package
(5)
39
T
stg
Storage temperature range –65 150 ° C
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) The input and output negative-voltage ratings may be exceeded if the input and output current ratings are observed.
(3) This value is limited to 5.5 V maximum.
(4) The package thermal impedance is calculated in accordance with JESD 51-7
(5) The package thermal impedance is calculated in accordance with JESD 51-5.