Datasheet
SCES336H − MAY 2000 − REVISED APRIL 2005
4
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
switching characteristics over recommended operating free-air temperature range,
V
CC
= 2.5 V ± 0.2 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
TO
LOAD
T
A
= 25°C SN54LV06A SN74LV06A
UNIT
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
LOAD
CAPACITANCE
MIN TYP MAX MIN MAX MIN MAX
UNIT
t
PLH
A
Y
C
L
= 15 pF
5.4
∗
10.4
∗
1
∗
13
∗
1 13
ns
t
PHL
A Y C
L
= 15 pF
7.2
∗
10.4
∗
1
∗
13
∗
1 13
ns
t
PLH
A
Y
C
L
= 50 pF
9.7 15.2 1 18 1 18
ns
t
PHL
A
Y
C
L
= 50 pF
9.3 15.2 1 18 1 18
ns
* On products compliant to MIL-PRF-38535, this parameter is not production tested.
switching characteristics over recommended operating free-air temperature range,
V
CC
= 3.3 V ± 0.3 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
TO
LOAD
T
A
= 25°C SN54LV06A SN74LV06A
UNIT
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
LOAD
CAPACITANCE
MIN TYP MAX MIN MAX MIN MAX
UNIT
t
PLH
A
Y
C
L
= 15 pF
4.1
∗
7.1
∗
1
∗
8.5
∗
1 8.5
ns
t
PHL
A Y C
L
= 15 pF
4.9
∗
7.1
∗
1
∗
8.5
∗
1 8.5
ns
t
PLH
A
Y
C
L
= 50 pF
7.1 10.6 1 12 1 12
ns
t
PHL
A
Y
C
L
= 50 pF
6.4 10.6 1 12 1 12
ns
* On products compliant to MIL-PRF-38535, this parameter is not production tested.
switching characteristics over recommended operating free-air temperature range,
V
CC
= 5 V ± 0.5 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
TO
LOAD
T
A
= 25°C SN54LV06A SN74LV06A
UNIT
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
LOAD
CAPACITANCE
MIN TYP MAX MIN MAX MIN MAX
UNIT
t
PLH
A
Y
C
L
= 15 pF
3
∗
5.5
∗
1
∗
6.5
∗
1 6.5
ns
t
PHL
A Y C
L
= 15 pF
3.3
∗
5.5
∗
1
∗
6.5
∗
1 6.5
ns
t
PLH
A
Y
C
L
= 50 pF
4.8 7.5 1 8.5 1 8.5
ns
t
PHL
A
Y
C
L
= 50 pF
4.4 7.5 1 8.5 1 8.5
ns
* On products compliant to MIL-PRF-38535, this parameter is not production tested.
noise characteristics, V
CC
= 3.3 V, C
L
= 50 pF, T
A
= 25°C (see Note 5)
PARAMETER
SN74LV06A
UNIT
PARAMETER
MIN TYP MAX
UNIT
V
OL(P)
Quiet output, maximum dynamic V
OL
0.5 0.8 V
V
OL(V)
Quiet output, minimum dynamic V
OL
−0.1 −0.8 V
V
OH(V)
Quiet output, minimum dynamic V
OH
3.3 V
V
IH(D)
High-level dynamic input voltage 2.31 V
V
IL(D)
Low-level dynamic input voltage 0.99 V
NOTE 5: Characteristics are for surface-mount packages only.
operating characteristics, T
A
= 25°C
PARAMETER TEST CONDITIONS V
CC
TYP UNIT
C
pd
Power dissipation capacitance
C
L
= 50 pF,
f = 10 MHz
3.3 V 2.6
pF
C
pd
Power dissipation capacitance
C
L
= 50 pF,
f = 10 MHz
5 V 4.7
pF
( &)!*$'!& "!&"%*& +*!#" & % )!*$'3% !*
%2& +'% !) %3%-!+$%&. ('*'"%*" '' '& !%*
+%")"'!& '*% %2& 2!'-. %/' &*#$%& *%%*3% % *2 !
"'&2% !* "!&&#% %% +*!#" 0!# &!"%.