Datasheet

SN54LS240, SN54LS241, SN54LS244, SN54S240, SN54S241, SN54S244
SN74LS240, SN74LS241, SN74LS244, SN74S240, SN74S241, SN74S244
OCTAL BUFFERS AND LINE DRIVERS WITH 3-STATE OUTPUTS
SDLS144C − APRIL 1985 − REVISED MAY 2010
7
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
TEST CONDITIONS
SN54LS’ SN74LS’
UNIT
PARAMETER
TEST CONDITIONS
MIN TYP
MAX MIN TYP
MAX
UNIT
V
IK
V
CC
= MIN, I
I
= −18 mA −1.5 −1.5 V
Hysteresis
(V
T+
− V
T−
)
V
CC
= MIN 0.2 0.4 0.2 0.4 V
V
CC
= MIN,
I
OH
= −3 mA
V
IH
= 2 V, V
IL
= MAX, 2.4 3.4 2.4 3.4
V
V
OH
V
CC
= MIN,
I
OH
= MAX
V
IH
= 2 V, V
IL
= 0.5 V, 2 2
V
V
CC
= MIN,
V 2V
I
OL
= 12 mA 0.4 0.4
V
V
OL
V
CC
=
MIN
,
V
IL
= MAX
V
IH
= 2 V,
I
OL
= 24 mA 0.5
V
I
OZH
V
CC
= MAX,
V
IL
= MAX
V
IH
= 2 V, V
O
= 2.7 V 20 20 µA
I
OZL
V
CC
= MAX,
V
IL
= MAX
V
IH
= 2 V, V
O
= 0.4 V −20 −20 µA
I
I
V
CC
= MAX, V
I
= 7 V 0.1 0.1 mA
I
IH
V
CC
= MAX, V
I
= 2.7 V 20 20 µA
I
IL
V
CC
= MAX, V
IL
= 0.4 V −0.2 −0.2 mA
I
OS
§
V
CC
= MAX, −40 −225 −40 −225 mA
Outputs high All 17 27 17 27
V MAX
Outputs low
’LS240 26 44 26 44
I
CC
V
CC
= MAX,
Output open
Outputs low
’LS241, ’LS244 27 46 27 46
mA
O
u
t
pu
t
open
Outputs disabled
’LS240 29 50 29 50
mA
Outputs disabled
’LS241, ’LS244 32 54 32 54
For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
All typical values are at V
CC
= 5 V, T
A
= 25°C.
§
Not more than one output should be shorted at a time, and duration of the short-circuit should not exceed one second.
switching characteristics, V
CC
= 5 V, T
A
= 25°C (see Figure 1)
PARAMETER
TEST CONDITIONS
’LS240 ’LS241, ’LS244
UNIT
PARAMETER TEST CONDITIONS
MIN TYP MAX MIN TYP MAX
UNIT
t
PLH
R 667
C 45 pF
9 14 12 18
ns
t
PHL
R
L
= 667 Ω,
C
L
= 45 pF
12 18 12 18
ns
t
PZL
R 667
C 45 F
20 30 20 30
ns
t
PZH
R
L
= 667 Ω,
C
L
= 45 pF
15 23 15 23
ns
t
PLZ
R 667
C 5pF
10 20 10 20
ns
t
PHZ
R
L
= 667 Ω, C
L
= 5 pF
15 25 15 25
ns