Datasheet
SDLS213B − DECEMBER 1983 − REVISED NOVEMBER 2004
10
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
PARAMETER MEASUREMENT INFORMATION
B
†
CLR
Q
Q
3 V
3 V
0 V
0 V
V
OH
V
OH
V
OL
V
OL
t
w
≥ 60 ns
t
PLH
t
PHL
t
PHL
t
PLH
CONDITION 1: TRIGGER FROM B, THEN CLR
B
†
CLR
Q
3 V
3 V
0 V
0 V
V
OH
V
OL
≥ 60 ns
CONDITION 2: TRIGGER FROM B, THEN CLR
B
†
CLR
Q
3 V
3 V
0 V
0 V
V
OH
V
OL
≥ 50 ns
CONDITION 3: CLR
OVERRIDING B, THEN TRIGGER FROM B
t
su
≥ 0
t
w
Triggered
Not Triggered
†
A is low.
Figure 1. Switching Characteristics