Datasheet

SN54165, SN54LS165A, SN74165, SN74LS165A
PARALLEL-LOAD 8-BIT SHIFT REGISTERS
SDLS062D OCTOBER 1976 REVISED FEBRUARY 2002
6
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
TEST CONDITIONS
SN54165 SN74165
UNIT
TEST
CONDITIONS
MIN TYP
MAX MIN TYP
MAX
UNIT
V
IH
High-level input voltage 2 2 V
V
IL
Low-level input voltage 0.8 0.8 V
V
IK
Input clamp voltage V
CC
= MIN, I
I
= 12 mA 1.5 1.5 V
V
OH
High-level output voltage
V
CC
= MIN,
V
IL
= 0.8 V,
V
IH
= 2 V,
I
OH
= 800 A
2.4 3.4 2.4 3.4 V
V
OL
Low-level output voltage
V
CC
= MIN,
V
IL
= 0.8 V,
V
IH
= 2 V,
I
OL
= 16 mA
0.2 0.4 0.2 0.4 V
I
I
Input current at maximum input voltage V
CC
= MAX, V
I
= 5.5 V 1 1 mA
I
IH
High level in
p
ut current
SH/LD
V
CC
= MAX
V
I
=24V
80 80
µA
I
IH
High
-
level
input
current
Other inputs
V
CC
=
MAX
,
V
I
=
2
.
4
V
40 40
µ
A
I
IL
Low level in
p
ut current
SH/LD
V
CC
= MAX
V
I
=04V
3.2 3.2
mA
I
IL
Low
-
level
input
current
Other inputs
V
CC
=
MAX
,
V
I
=
0
.
4
V
1.6 1.6
mA
I
OS
Short-circuit output current
§
V
CC
= MAX 20 55 18 55 mA
I
CC
Supply current V
CC
= MAX, See Note 4 42 63 42 63 mA
NOTE 4: With the outputs open, CLK INH and CLK at 4.5 V, and a clock pulse applied to SH/LD, I
CC
is measured first with the parallel inputs
at 4.5 V, then with the parallel inputs grounded.
For conditions shown as MIN or MAX, use the appropriate values specified under recommended operating conditions.
All typical values are at V
CC
= 5 V, T
A
= 25°C.
§
Not more than one output should be shorted at a time.
SN54165 and SN74165 switching characteristics, V
CC
= 5 V, T
A
= 25°C (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
TEST CONDITIONS MIN TYP MAX
UNIT
f
max
20 26 MHz
t
PLH
LD
Any
C
L
=15
p
FR
L
= 400
21 31
ns
t
PHL
LD
Any
C
L
=
15
pF
,
R
L
=
400
27 40
ns
t
PLH
CLK
Any
C
L
=15
p
FR
L
= 400
16 24
ns
t
PHL
CLK
Any
C
L
=
15
pF
,
R
L
=
400
21 31
ns
t
PLH
H
Q
H
C
L
=15
p
FR
L
= 400
11 17
ns
t
PHL
H
Q
H
C
L
=
15
pF
,
R
L
=
400
24 36
ns
t
PLH
H
Q
H
C
L
=15
p
FR
L
= 400
18 27
ns
t
PHL
H
Q
H
C
L
=
15
pF
,
R
L
=
400
18 27
ns
f
max
= maximum clock frequency, t
PLH
= propagation delay time, low-to-high-level output, t
PHL
= propagation delay time, high-to-low-level output
The SN54165 and SN74165 devices
are obsolete and are no longer supplied
.