Datasheet

  
  
   
SDLS020E − MAY 1990 − REVISED FEBRUARY 2004
3
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
CC
7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage, V
I
(see Note 1) 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output voltage, V
O
(see Notes 1 and 2): SN54LS06, SN74LS06 30 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SN74LS16 15 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Package thermal impedance, θ
JA
(see Note 3): D package 86°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DB package 96°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
N package 80°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NS package 76°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
−65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values are with respect to GND.
2. This is the maximum voltage that should be applied to any output when it is in the off state.
3. The package thermal impedance is calculated in accordance with JESD 51-7.
recommended operating conditions (see Note 4)
SN54LS06
SN74LS06
SN74LS16
UNIT
MIN NOM MAX MIN NOM MAX
UNIT
V
CC
Supply voltage 4.5 5 5.5 4.75 5 5.25 V
V
IH
High-level input voltage 2 2 V
V
IL
Low-level input voltage 0.8 0.8 V
V
OH
’LS06 30 30
V
V
OH
High-level output voltage
SN74LS16
15
V
I
OL
Low-level output current 30 40 mA
T
A
Operating free-air temperature −55 125 0 70 °C
NOTE 4: All unused inputs of the device must be held at V
CC
or GND to ensure proper device operation. Refer to the TI application report,
Implications of Slow or Floating CMOS Inputs, literature number SCBA004.
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
SN54LS06
SN74LS06
SN74LS16
UNIT
PARAMETER
TEST CONDITIONS
MIN TYP
§
MAX MIN TYP
§
MAX
UNIT
V
IK
V
CC
= MIN, I
I
= −12 mA −1.5 −1.5 V
I
OH
V
CC
= MIN,
V
IL
= 0.8 V
’LS06, V
OH
= 30 V 0.25 0.25
mA
I
OH
V
CC
= MIN, V
IL
= 0.8 V
SN74LS16, V
OH
= 15 V
0.25
mA
I
OL
= 16 mA 0.25 0.4 0.25 0.4
V
OL
V
CC
= MIN, V
IH
= 2 V
I
OL
= 30 mA
0.7
V
V
OL
V
CC
= MIN,
V
IH
= 2 V
I
OL
= 40 mA 0.7
V
I
I
V
CC
= MAX, V
I
= 7 V 1 1 mA
I
IH
V
CC
= MAX, V
I
= 2.4 V 20 20 µA
I
IL
V
CC
= MAX, V
I
= 0.4 V −0.2 −0.2 mA
I
CCH
V
CC
= MAX 18 18 mA
I
CCL
V
CC
= MAX 60 60 mA
For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
§
All typical values are at V
CC
= 5 V, and T
A
= 25°C.
The SN74LS16 is obsolete
a
nd is no longer supplied
.