Datasheet
SCLS068E − NOVEMBER 1988 − REVISED AUGUST 2003
5
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
operating characteristics, V
CC
= 5 V, T
A
= 25°C
PARAMETER TEST CONDITIONS TYP UNIT
C
pd
Power dissipation capacitance No load 30 pF
PARAMETER MEASUREMENT INFORMATION
VOLTAGE WAVEFORMS
SETUP AND HOLD AND INPUT RISE AND FALL TIMES
VOLTAGE WAVEFORMS
PULSE DURATIONS
t
h
t
su
1.3 V
1.3 V1.3 V
0.3 V0.3 V
2.7 V 2.7 V
3 V
3 V
0 V
0 V
t
r
t
f
Reference
Input
Data
Input
1.3 V
High-Level
Pulse
1.3 V
3 V
0 V
1.3 V
1.3 V
3 V
0 V
t
w
Low-Level
Pulse
VOLTAGE WAVEFORMS
PROPAGATION DELAY AND OUTPUT RISE AND FALL TIMES
1.3 V
1.3 V1.3 V
10%10%
90% 90%
3 V
V
OH
V
OL
0 V
t
r
t
f
Input
In-Phase
Output
1.3 V
t
PLH
t
PHL
1.3 V 1.3 V
10% 10%
90%90%
V
OH
V
OL
t
r
t
f
t
PHL
t
PLH
Out-of-
Phase
Output
Test
Point
From Output
Under Test
C
L
= 50 pF
(see Note A)
LOAD CIRCUIT
NOTES: A. C
L
includes probe and test-fixture capacitance.
B. Phase relationships between waveforms were chosen arbitrarily. All input pulses are supplied by generators having the following
characteristics: PRR ≤ 1 MHz, Z
O
= 50 Ω, t
r
= 6 ns, t
f
= 6 ns.
C. The outputs are measured one at a time with one input transition per measurement.
D. For clock inputs, f
max
is measured when the input duty cycle is 50%.
E. t
PLH
and t
PHL
are the same as t
pd
.
Figure 1. Load Circuit and Voltage Waveforms