Datasheet
SCLS068E − NOVEMBER 1988 − REVISED AUGUST 2003
3
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
†
Supply voltage range, V
CC
−0.5 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input clamp current, I
IK
(V
I
< 0 or V
I
> V
CC
) (see Note 1) ±20 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output clamp current, I
OK
(V
O
< 0 or V
O
> V
CC
) (see Note 1) ±20 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous output current, I
O
(V
O
= 0 to V
CC
) ±25 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous current through V
CC
or GND ±50 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Package thermal impedance, θ
JA
(see Note 2): DB package 70°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DW package 58°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
N package 69°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NS package 60°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PW package 83°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
−65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
2. The package thermal impedance is calculated in accordance with JESD 51-7.
recommended operating conditions (see Note 3)
SN54HCT273 SN74HCT273
UNIT
MIN NOM MAX MIN NOM MAX
UNIT
V
CC
Supply voltage 4.5 5 5.5 4.5 5 5.5 V
V
IH
High-level input voltage V
CC
= 4.5 V to 5.5 V 2 2 V
V
IL
Low-level input voltage V
CC
= 4.5 V to 5.5 V 0.8 0.8 V
V
I
Input voltage 0 V
CC
0 V
CC
V
V
O
Output voltage 0 V
CC
0 V
CC
V
∆t/∆v Input transition rise/fall time 500 500 ns
T
A
Operating free-air temperature −55 125 −40 85 °C
NOTE 3: All unused inputs of the device must be held at V
CC
or GND to ensure proper device operation. Refer to the TI application report,
Implications of Slow or Floating CMOS Inputs, literature number SCBA004.
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
V
CC
T
A
= 25°C SN54HCT273 SN74HCT273
UNIT
PARAMETER
TEST CONDITIONS
V
CC
MIN TYP MAX MIN MAX MIN MAX
UNIT
V
OH
V
I
= V
IH
or V
IL
I
OH
= −20 µA 4.5 V 4.4 4.499 4.4 4.4
V
V
OH
V
I
= V
IH
or V
IL
I
OH
= −4 mA 4.5 V 3.98 4.30 3.7 3.84
V
V
OL
V
I
= V
IH
or V
IL
I
OL
= 20 µA 4.5 V 0.001 0.1 0.1 0.1
V
V
OL
V
I
= V
IH
or V
IL
I
OL
= 4 mA 4.5 V 0.17 0.26 0.4 0.33
V
I
I
V
I
= V
CC
or 0 5.5 V ±0.1 ±100 ±1000 ±1000 nA
I
CC
V
I
= V
CC
or 0, I
O
= 0 5.5 V 8 160 80 µA
∆I
CC
‡
One input at 0.5 V or 2.4 V,
Other inputs at 0 or V
CC
5.5 V 1.4 2.4 3 2.9 mA
C
i
4.5 V
to 5.5 V
3 10 10 10 pF
‡
This is the increase in supply current for each input that is at one of the specified TTL voltage levels, rather than 0 V or V
CC
.
0 $&'"%$ $#'$ ('! $ # &'"%1# '
#/$ (%# & #1#*("#$+ %'%#' %% %$ #'
(#&%$ %'# #/$ /%*+ #,% $'!"#$ '##'1# # '/
%$/# ' $$!# ## ('! -! $#+