Datasheet
SCLS573 − MARCH 2004
5
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
switching characteristics over recommended operating free-air temperature range,
V
CC
= 2 V, C
L
= 50 pF (unless otherwise noted) (see Figures 9−14)
PARAMETER
FROM
TO
T
A
= 25°C −40 TO 85°C −40 TO 125°C
UNIT
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
MIN TYP MAX MIN MAX MIN MAX
UNIT
t
PLH
t
PHL
Propagation
delay time
COM or Yn Yn or COM 14.5 19.5 33 12 34 11 35 ns
t
PLH
t
PHL
Propagation
delay time
Channel Select COM or Yn 19.6 24.5 38 15.4 40 13.8 42 ns
t
PZH
t
PZL
Enable
delay time
INH COM or Yn 19.4 23.6 47.5 15.8 52.5 14.5 57.5 ns
t
PHZ
t
PLZ
Disable
delay time
INH COM or Yn 39.5 48.4 100 39.3 105 39 115 ns
switching characteristics over recommended operating free-air temperature range,
V
CC
= 3 V, C
L
= 50 pF (unless otherwise noted) (see Figures 9−14)
PARAMETER
FROM
TO
T
A
= 25°C −40 TO 85°C −40 TO 125°C
UNIT
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
MIN TYP MAX MIN MAX MIN MAX
UNIT
t
PLH
t
PHL
Propagation
delay time
COM or Yn Yn or COM 8.6 12 16.5 6.5 18 5.8 19.5 ns
t
PLH
t
PHL
Propagation
delay time
Channel Select COM or Yn 12.4 14.6 20 9.3 21.5 8.2 23 ns
t
PZH
t
PZL
Enable
delay time
INH COM or Yn 12.1 13.8 45 9.2 50 8.5 55 ns
t
PHZ
t
PLZ
Disable
delay time
INH COM or Yn 35.2 44.5 90 35.5 100 35 110 ns
switching characteristics over recommended operating free-air temperature range,
V
CC
= 3.3 V, C
L
= 50 pF (unless otherwise noted) (see Figures 9−14)
PARAMETER
FROM
TO
T
A
= 25°C −40 TO 85°C −40 TO 125°C
UNIT
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
MIN TYP MAX MIN MAX MIN MAX
UNIT
t
PLH
t
PHL
Propagation
delay time
COM or Yn Yn or COM 7.9 11 15 5.8 16.5 5 18.5 ns
t
PLH
t
PHL
Propagation
delay time
Channel Select COM or Yn 11.4 13.5 17.5 8.5 19 7.5 22 ns
t
PZH
t
PZL
Enable
delay time
INH COM or Yn 11.2 12.7 42.5 8.4 47.5 7.4 52.5 ns
t
PHZ
t
PLZ
Disable
delay time
INH COM or Yn 34.6 43.9 85 34.6 95 34.5 105 ns