Datasheet
SCLS573 − MARCH 2004
3
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
recommended operating conditions (see Note 4)
MIN MAX UNIT
V
CC
Supply voltage 2 6 V
V
CC
= 2 V 1.5
High-level input voltage,
V
CC
= 3 V 2.1
V
IH
High-level input voltage,
control inputs
V
CC
= 3.3 V 2.3
V
V
IH
control inputs
V
CC
= 4.5 V 3.15
V
V
CC
= 6 V 4.2
V
CC
= 2 V 0.5
Low-level input voltage,
V
CC
= 3 V 0.9
V
IL
Low-level input voltage,
control inputs
V
CC
= 3.3 V 1
V
V
IL
control inputs
V
CC
= 4.5 V 1.35
V
V
CC
= 6 V 1.8
V
I
Control input voltage 0 V
CC
V
V
IO
Input/output voltage 0 V
CC
V
V
CC
= 2 V 1000
V
CC
= 3 V 800
∆t/∆v Input transition rise or fall rate
V
CC
= 3.3 V
700
ns
∆t/∆v
Input transition rise or fall rate
V
CC
= 4.5 V 500
ns
V
CC
= 6 V 400
T
A
Operating free-air temperature −40 125 °C
NOTE 4: All unused control inputs of the device must be held at V
CC
or GND to ensure proper device operation. Refer to the TI application report,
Implications of Slow or Floating CMOS Inputs, literature number SCBA004.