Datasheet

SN74HC4066
QUADRUPLE BILATERAL ANALOG SWITCH
SCLS325G MARCH 1996 REVISED JULY 2003
4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
switching characteristics over recommended operating free-air temperature range
FROM TO TEST
V
CC
T
A
= 25 C
MIN
MAX
UNIT
(INPUT) (OUTPUT) CONDITIONS
V
CC
MIN TYP MAX
MIN
MAX
UNIT
t
Pti
C50F
2 V 10 60 75
t
PLH
,
t
PHL
Propagation
delay time
A or B B or A
C
L
= 50 pF
(see Figure 4)
4.5 V 4 12 15
ns
t
PHL
delay
time
(see
Figure
4)
6 V 3 10 13
t
Sith
R
L
=
1k,
2 V 70 180 225
t
PZH
,
t
PZL
Switch
turn
-
on time
C A or B
R
L
=
1
k
,
C
L
= 50 pF
4.5 V 21 36 45
ns
t
PZL
turn-on
time
L
(see Figure 5)
6 V 18 31 38
t
Sith
R
L
=
1k,
2 V 50 200 250
t
PLZ
,
t
PHZ
Switch
turn
-
off time
C A or B
R
L
=
1
k
,
C
L
= 50 pF
4.5 V 25 40 50
ns
t
PHZ
turn-off
time
L
(see Figure 5)
6 V 22 34 43
Control
C
L
= 15 pF,
R
L
=1k
2 V 15
f
I
Control
input
frequency
C A or B
R
L
=
1
k
,
V
C
= V
CC
or GND,
VV/2
4.5 V 30
MHz
f
requency
V
O
=
V
CC
/2
(see Figure 6)
6 V 30
Control
feed-through
C
AorB
C
L
= 50 pF,
R
in
= R
L
= 600 ,
V
C
=V
CC
or GND
4.5 V 15
mV
feed
-
through
noise
C
A
or
B
V
C
=
V
CC
or
GND
,
f
in
= 1 MHz
(see Figure 7)
6 V 20
(rms)
operating characteristics, V
CC
= 4.5 V, T
A
= 25°C
PARAMETER
TEST CONDITIONS TYP UNIT
C
pd
Power dissipation capacitance per gate C
L
= 50 pF, f = 1 MHz 45 pF
Minimum through bandwidth, A to B or B to A
[20 log (V
O
/V
I
)] = 3 dB
C
L
= 50 pF,
V
C
= V
CC
R
L
= 600 ,
(see Figure 8)
30 MHz
Crosstalk between any switches
C
L
= 10 pF,
f
in
= 1 MHz
R
L
= 50 ,
(see Figure 9)
45 dB
Feed through, switch off, A to B or B to A
C
L
= 50 pF,
f
in
= 1 MHz
R
L
= 600 ,
(see Figure 10)
42 dB
Amplitude distortion rate, A to B or B to A
C
L
= 50 pF,
f
in
= 1 kHz
R
L
= 10 k,
(see Figure 11)
0.05%
Adjust the input amplitude for output = 0 dBm at f = 1 MHz. Input signal must be a sine wave.
Adjust the input amplitude for input = 0 dBm at f = 1 MHz. Input signal must be a sine wave.