Datasheet


   
SCLS473A − APRIL 2003 − REVISED JANUARY 2004
7
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
switching characteristics over recommended operating free-air temperature range, C
L
= 50 pF
(unless otherwise noted) (see Figure 1)
PARAMETER
FROM
TO
V
CC
T
A
= 25°C
MIN
MAX
UNIT
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
V
CC
MIN TYP MAX
MIN
MAX
UNIT
2 V 6 13 4.2
f
max
4.5 V 31 50 21
MHz
f
max
6 V 36 62 25
MHz
2 V 80 150 225
SH/LD Q
H
or Q
H
4.5 V 20 30 45
SH/LD
Q
H
or Q
H
6 V 16 26 38
2 V 75 150 225
t
pd
CLK Q
H
or Q
H
4.5 V 15 30 45
ns
t
pd
CLK
Q
H
or Q
H
6 V 13 26 38
ns
2 V 75 150 225
H Q
H
or Q
H
4.5 V 15 30 45
H
Q
H
or Q
H
6 V 13 26 38
2 V 38 75 110
t
t
Any
4.5 V 8 15 22
ns
t
t
Any
6 V 6 13 19
ns
operating characteristics, T
A
= 25°C
PARAMETER TEST CONDITIONS TYP UNIT
C
pd
Power dissipation capacitance No load 75 pF