Datasheet

SCLS473A − APRIL 2003 − REVISED JANUARY 2004
5
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
V
CC
T
A
= 25°C
MIN
MAX
UNIT
PARAMETER
TEST CONDITIONS
V
CC
MIN TYP MAX
MIN
MAX
UNIT
2 V 1.9 1.998 1.9
I
OH
= −20 µA
4.5 V 4.4 4.499 4.4
V
OH
V
I
= V
IH
or V
IL
I
OH
= −20 µA
6 V 5.9 5.999 5.9
V
V
OH
V
I
= V
IH
or V
IL
I
OH
= −4 mA 4.5 V 3.98 4.3 3.7
V
I
OH
= −5.2 mA 6 V 5.48 5.8 5.2
2 V 0.002 0.1 0.1
I
OL
= 20 µA
4.5 V 0.001 0.1 0.1
V
OL
V
I
= V
IH
or V
IL
I
OL
= 20 µA
6 V 0.001 0.1 0.1
V
V
OL
V
I
= V
IH
or V
IL
I
OL
= 4 mA 4.5 V 0.17 0.26 0.4
V
I
OL
= 5.2 mA 6 V 0.15 0.26 0.4
I
I
V
I
= V
CC
or 0 6 V ±0.1 ±100 ±1000 nA
I
CC
V
I
= V
CC
or 0, I
O
= 0 6 V 8 160 µA
C
i