Datasheet

www.ti.com
PARAMETER MEASUREMENT INFORMATION
From Output
Under Test
C
L
= 50 pF
(see Note A)
LOAD CIRCUIT FOR A OUTPUTS
S1
Open
GND
500
500
TEST
t
PLH
/t
PHL
t
PLZ
/t
PZL
t
PHZ
/t
PZH
S1
Open
6 V
GND
t
PLH
t
PHL
Output
Control
Output
Waveform 1
S1 at 6 V
(see Note B)
Output
Waveform 2
S1 at GND
(see Note B)
V
OL
V
OH
t
PZL
t
PZH
t
PLZ
t
PHZ
3 V
0 V
V
OH
V
OL
0 V
V
OL
+ 0.3 V
V
OH
− 0.3 V
0 V
Input
3 V
3 V
VOLTAGE WAVEFORMS
PROPAGATION DELAY TIMES
(A port to B port)
VOLTAGE WAVEFORMS
ENABLE AND DISABLE TIMES
(A port)
Output
1.5 V
Test
Point
C
L
= 30 pF
(see Note A)
From Output
Under Test
25
LOAD CIRCUIT FOR B OUTPUTS
0 V
V
OH
V
OL
Input
VOLTAGE WAVEFORMS
PROPAGATION DELAY TIMES
(B port to A port)
Output
1.5 V
NOTES: A. C
L
includes probe and jig capacitance.
B. Waveform 1 is for an output with internal conditions such that the output is low, except when disabled by the output control.
Waveform 2 is for an output with internal conditions such that the output is high, except when disabled by the output control.
C. All input pulses are supplied by generators having the following characteristics: PRR 10 MHz, Z
O
= 50 , t
r
2 ns, t
f
2 ns.
D. The outputs are measured one at a time, with one transition per measurement.
6 V
t
PLH
t
PHL
1.5 V 1.5 V
1.5 V
1.5 V
1.5 V
1.5 V 1.5 V
1.5 V
1 V 1 V
1 V 1 V
SN74GTLPH306
8-BIT LVTTL-TO-GTLP BUS TRANSCEIVER
SCES284E OCTOBER 1999 REVISED APRIL 2005
Figure 1. Load Circuits and Voltage Waveforms