Datasheet

www.ti.com
Electrical Characteristics
Hot-Insertion Specifications for A Port
Hot-Insertion Specifications for B Port
SN74GTLPH306
8-BIT LVTTL-TO-GTLP BUS TRANSCEIVER
SCES284E OCTOBER 1999 REVISED APRIL 2005
over recommended operating free-air temperature range for GTLP (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP
(1)
MAX UNIT
V
IK
V
CC
= 3.15 V, I
I
= –18 mA –1.2 V
V
CC
= 3.15 V to 3.45 V, I
OH
= –100 µ A V
CC
0.2
V
OH
A port I
OH
= –12 mA 2.4 V
V
CC
= 3.15 V
I
OH
= –24 mA 2
V
CC
= 3.15 V to 3.45 V, I
OL
= 100 µ A 0.2
A port I
OL
= 12 mA 0.4
V
CC
= 3.15 V
V
OL
I
OL
= 24 mA 0.5 V
I
OL
= 40 mA 0.4
B port V
CC
= 3.15 V
I
OL
= 50 mA 0.55
V
I
= 0 or V
CC
±5
A-port and
control inputs
I
I
(2)
V
CC
= 3.45 V V
I
= 5.5 V ±20 µ A
B port V
I
= 0 to 1.5 V ±5
I
BHL
(3)
A port V
CC
= 3.15 V, V
I
= 0.8 V 75 µ A
I
BHH
(4)
A port V
CC
= 3.15 V, V
I
= 2 V –75 µ A
I
BHLO
(5)
A port V
CC
= 3.45 V, V
I
= 0 to V
CC
500 µ A
I
BHHO
(6)
A port V
CC
= 3.45 V, V
I
= 0 to V
CC
–500 µ A
Outputs high 20
V
CC
= 3.45 V, I
O
= 0,
I
CC
A or B port V
I
(A-port or control input) = V
CC
or GND, Outputs low 20 mA
V
I
(B port) = V
TT
or GND
Outputs disabled 20
V
CC
= 3.45 V, One A-port or control input at V
CC
0.6 V,
I
CC
(7)
1.5 mA
Other A-port or control inputs at V
CC
or GND
C
i
Control inputs V
I
= 3.15 V or 0 4.5 5 pF
A port V
O
= 3.15 V or 0 7.5 9
C
io
pF
B port V
O
= 1.5 V or 0 7.5 9
(1) All typical values are at V
CC
= 3.3 V, T
A
= 25°C.
(2) For I/O ports, the parameter I
I
includes the off-state output leakage current.
(3) The bus-hold circuit can sink at least the minimum low sustaining current at V
IL
max. I
BHL
should be measured after lowering V
IN
to GND
and then raising it to V
IL
max.
(4) The bus-hold circuit can source at least the minimum high sustaining current at V
IH
min. I
BHH
should be measured after raising V
IN
to V
CC
and then lowering it to V
IH
min.
(5) An external driver must source at least I
BHLO
to switch this node from low to high.
(6) An external driver must sink at least I
BHHO
to switch this node from high to low.
(7) This is the increase in supply current for each input that is at the specified TTL voltage level, rather than V
CC
or GND.
over recommended operating free-air temperature range
PARAMETER TEST CONDITIONS MIN MAX UNIT
I
off
V
CC
= 0, V
I
or V
O
= 0 to 5.5 V 10 µ A
I
OZPU
V
CC
= 0 to 1.5 V, V
O
= 0.5 V to 3 V, OE = 0 ±30 µ A
I
OZPD
V
CC
= 1.5 V to 0, V
O
= 0.5 V to 3 V, OE = 0 ±30 µ A
over recommended operating free-air temperature range
PARAMETER TEST CONDITIONS MIN MAX UNIT
I
off
V
CC
= 0, V
I
or V
O
= 0 to 1.5 V 10 µ A
I
OZPU
V
CC
= 0 to 1.5 V, V
O
= 0.5 V to 1.5 V, OE = 0 ±30 µ A
I
OZPD
V
CC
= 1.5 V to 0, V
O
= 0.5 V to 1.5 V, OE = 0 ±30 µ A
5