Datasheet

SN74GTL1655
16-BIT LVTTL-TO-GTL/GTL+ UNIVERSAL BUS TRANSCEIVER
WITH LIVE INSERTION
SCBS696G – JULY 1997 – REVISED AUGUST 2001
2–9
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range, V
REF
= 1 V and
V
TT
= 1.5 V (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP
MAX UNIT
V
IK
V
CC
= 3 V, I
I
= –18 mA –1.2 V
V
CC
= 3 V to 3.6 V, I
OH
= –100 µA V
CC
–0.2
V
OH
A port
V
CC
=3V
I
OH
= –12 mA 2.4
V
V
CC
=
3
V
I
OH
= –24 mA 2.2
V
CC
= 3 V to 3.6 V, I
OL
= 100 µA 0.2
A port
V
CC
=3V
I
OL
= 12 mA 0.4
V
OL
V
CC
=
3
V
I
OL
= 24 mA 0.55
V
V
OL
I
OL
= 40 mA 0.2
V
B port V
CC
= 3 V
I
OL
= 80 mA 0.4
I
OL
= 100 mA 0.5
I
I
Control inputs
V
CC
=36V
V
I
= V
CC
or GND ±10
µA
I
I
B port
V
CC
=
3
.
6
V
V
I
= V
TT
or GND ±10
µ
A
I
off
V
CC
= 0, V
I
or V
O
= 0 to 3.6 V ±100 µA
V
CC
=3V
V
I
= 0.8 V 75
I
I(hold)
A port
V
CC
=
3
V
V
I
= 2 V –75
µA
()
V
CC
= 3.6 V
, V
I
= 0 to V
CC
±500
I
OZH
B port V
CC
= 3.6 V, V
O
= 1.5 V 10 µA
I
OZL
B port V
CC
= 3.6 V, V
O
= 0.4 V –10 µA
I
OZ
§
A port V
CC
= 3.6 V, V
O
= V
CC
or GND ±10 µA
I
OZPU
A port V
CC
= 0 to 3.6 V, V
O
= 0.5 V to 3 V, OE = low ±50 µA
I
OZPD
A port V
CC
= 3.6 V to 0, V
O
= 0.5 V to 3 V, OE = low ±50 µA
V36VI0
Outputs high 80
I
CC
A or B port
V
CC
= 3.6 V, I
O
= 0,
V
I
=V
CC
or GND
Outputs low 80
mA
V
I
=
V
CC
or
GND
Outputs disabled 80
I
CC
Except B port
V
CC
= 3.6 V, A-port or control inputs at V
CC
or GND,
One input at V
CC
– 0.6 V
1 mA
C
i
Control inputs V
I
= V
CC
or 0 3 5 pF
C
i
A port
V
O
=V
CC
or 0
5 6
p
F
C
io
B port
V
O
=
V
CC
or
0
6 8
pF
All typical values are at V
CC
= 3.3 V, T
A
= 25°C.
This is the bus-hold maximum dynamic current. It is the minimum overdrive current required to switch the input from one state to another.
§
For I/O ports, the parameter I
OZ
includes the input leakage current.
This is the increase in supply current for each input that is at the specified TTL voltage level rather than V
CC
or GND.
live-insertion specifications over recommended operating free-air temperature range
PARAMETER TEST CONDITIONS MIN MAX UNIT
I
CC
(BIAS V
CC
)
V
CC
= 0 to 3 V
V
O
(B
p
ort)=0to12V
V
I
(BIAS V
CC
)=3Vto36V
5 mA
I
CC
(BIAS
V
CC
)
V
CC
= 3 V to 3.6 V
V
O
(B
port)
=
0
to
1
.
2
V
,
V
I
(BIAS
V
CC
)
=
3
V
to
3
.
6
V
10 µA
V
O
B port V
CC
= 0, V
I
(BIAS V
CC
) = 3.3 V 1 1.2 V
V
CC
= 0, V
O
(B port) = 0.4 V, V
I
(BIAS V
CC
) = 3 V to 3.6 V –1
I
O
B port
V
CC
= 0 to 3.6 V, OE = 3.3 V 100
µA
V