Datasheet
SN54F86, SN74F86
QUADRUPLE 2-INPUT EXCLUSIVE-OR GATES
SDFS019B – JANUARY 1989 – REVISED JANUARY 1997
3
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
SN54F86 SN74F86
UNIT
PARAMETER
TEST
CONDITIONS
MIN TYP
†
MAX MIN TYP
†
MAX
UNIT
V
IK
V
CC
= 4.5 V, I
I
= –18 mA –1.2 –1.2 V
V
OH
V
CC
= 4.5 V, I
OH
= –1 mA 2.5 3.4 2.5 3.4
V
V
OH
V
CC
= 4.75 V, I
OH
= –1 mA 2.7
V
V
OL
V
CC
= 4.5 V, I
OL
= 20 mA 0.3 0.5 0.3 0.5 V
I
I
V
CC
= 5.5 V, V
I
= 7 V 0.1 0.1 mA
I
IH
V
CC
= 5.5 V, V
I
= 2.7 V 20 20 µA
I
IL
V
CC
= 5.5 V, V
I
= 0.5 V – 0.6 – 0.6 mA
I
OS
‡
V
CC
= 5.5 V, V
O
= 0 –60 –150 –60 –150 mA
I
CCH
V
CC
= 5.5 V, See Note 3 15 23 15 23 mA
I
CCL
V
CC
= 5.5 V, V
I
= 4.5 V 18 28 18 28 mA
†
All typical values are at V
CC
= 5 V, T
A
= 25°C.
‡
Not more than one output should be shorted at a time, and the duration of the short circuit should not exceed one second.
NOTE 3: I
CCH
is measured with outputs open, and the A or B input (not both) at 4.5 V. Remaining inputs are grounded.
switching characteristics (see Figure 1)
PARAMETER
FROM
(
INPUT
)
TO
(
OUTPUT
)
V
CC
= 5 V,
C
L
= 50 pF,
R
L
= 500 Ω,
T
A
= 25°C
V
CC
= 4.5 V to 5.5 V,
C
L
= 50 pF,
R
L
= 500Ω,
T
A
= MIN to MAX
§
UNIT
(INPUT)
(OUTPUT)
′F86 SN54F86 SN74F86
MIN TYP MAX MIN MAX MIN MAX
t
PLH
A or B
Y
3 4 5.5 3 7 3 6.5
ns
t
PHL
(other input low)
Y
3 4.2 5.5 2.6 8 3 6.5
ns
t
PLH
A or B
Y
3.5 5.3 7 3.5 10 3.5 8
ns
t
PHL
(other input high)
Y
3 4.7 6.5 3 8 3 7.5
ns
§
For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.