Datasheet
SN54F74, SN74F74
DUAL POSITIVE-EDGE-TRIGGERED D-TYPE FLIP-FLOPS
WITH CLEAR AND PRESET
SDFS046A – MARCH 1987 – REVISED OCTOBER 1993
2–3
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
recommended operating conditions
SN54F74 SN74F74
UNIT
MIN NOM MAX MIN NOM MAX
UNIT
V
CC
Supply voltage 4.5 5 5.5 4.5 5 5.5 V
V
IH
High-level input voltage 2 2 V
V
IL
Low-level input voltage 0.8 0.8 V
I
IK
Input clamp current –18 –18 mA
I
OH
High-level output current –1 –1 mA
I
OL
Low-level output current 20 20 mA
T
A
Operating free-air temperature –55 125 0 70 °C
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
SN54F74 SN74F74
UNIT
PARAMETER
TEST
CONDITIONS
MIN TYP
†
MAX MIN TYP
†
MAX
UNIT
V
IK
V
CC
= 4.5 V, I
I
= –18 mA –1.2 –1.2 V
V
OH
V
CC
= 4.5 V, I
OH
= – 1 mA 2.5 3.4 2.5 3.4
V
V
OH
V
CC
= 4.75 V, I
OH
= – 1 mA 2.7
V
V
OL
V
CC
= 4.5 V, I
OL
= 20 mA 0.3 0.5 0.3 0.5 V
I
I
V
CC
= 5.5 V, V
I
= 7 V 0.1 0.1 mA
I
IH
V
CC
= 5.5 V, V
I
= 2.7 V 20 20 µA
I
IL
Data, CLK
V
CC
=55V
V
I
=05V
– 0.6 – 0.6
mA
I
IL
PRE or CLR
V
CC
=
5
.
5
V
,
V
I
=
0
.
5
V
– 1.8 – 1.8
mA
I
OS
‡
V
CC
= 5.5 V, V
O
= 0 –60 –150 –60 –150 mA
I
CC
V
CC
= 5.5 V, See Note 2 10.5 16 10.5 16 mA
†
All typical values are at V
CC
= 5 V, T
A
= 25°C.
‡
Not more than one output should be shorted at a time, and the duration of the short circuit should not exceed one second.
NOTE 2: I
CC
is measured with D, CLK, and PRE
grounded then with D, CLK, and CLR grounded.
timing requirements over recommended ranges of supply voltage and operating free-air
temperature (unless otherwise noted)
V
CC
= 5 V,
T
A
= 25°C
SN54F74 SN74F74
UNIT
′F74
UNIT
MIN MAX MIN MAX MIN MAX
f
clock
Clock frequency 0 100 0 80 0 100 MHz
t
Pulse duration
CLK high, PRE or CLR low 4 4 4
ns
t
w
P
u
lse
d
u
ration
CLK low 5 6 5
ns
Setup time data before CLK↑
High 2 3 2
t
su
S
e
t
up
ti
me,
d
a
t
a
b
e
f
ore
CLK↑
Low 3 4 3
ns
su
Setup time, inactive-state before CLK↑
§
PRE or CLR to CLK 2 3 2
t
h
Hold time data after CLK↑
High 1 2 1
ns
t
h
Hold
time
,
data
after
CLK↑
Low 1 2 1
ns
§
Inactive-state setup time is also referred to as recovery time.