Datasheet
SN74F175
QUADRUPLE D-TYPE FLIP-FLOP
WITH CLEAR
SDFS058B – D293, MARCH 1987 – REVISED MAY 2002
3
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP
†
MAX UNIT
V
IK
V
CC
= 4.5 V, I
I
= –18 mA –1.2 V
V
OH
V
CC
= 4.5 V, I
OH
= –1 mA 2.5 3.4
V
V
OH
V
CC
= 4.75 V, I
OH
= –1 mA 2.7
V
V
OL
V
CC
= 4.5 V, I
OL
= 20 mA 0.3 0.5 V
I
I
V
CC
= 5.5 V, V
I
= 7 V 0.1 mA
I
IH
V
CC
= 5.5 V, V
I
= 2.7 V 20 µA
I
IL
V
CC
= 5.5 V, V
I
= 0.5 V – 0.6 mA
I
OS
‡
V
CC
= 5.5 V, V
O
= 0 –60 –150 mA
I
CC
V
CC
= 5.5 V, See Note 4 22.5 34 mA
†
All typical values are at V
CC
= 5 V, T
A
= 25°C.
‡
Not more than one output should be shorted at a time, and the duration of the short circuit should not exceed one second.
NOTE 4: I
CC
is measured with outputs open, with 4.5 V applied to all data inputs after a momentary ground, followed by 4.5 V applied to CLK.
timing requirements over recommended ranges of supply voltage and operating free-air
temperature (unless otherwise noted)
V
CC
= 5 V,
T
A
= 25°C
MIN MAX UNIT
MIN MAX
f
clock
Clock frequency 100 100 MHz
CLK high 4 4
t
w
Pulse duration
CLK low
5 5
ns
CLR low 5 5
t
Setup time, data before CLK↑
High or low 3 3
ns
t
su
Setup time, inactive state, data before CLK↑
§
CLR high 5 5
ns
t
h
Hold time, data after CLK↑ High or low 1 1 ns
§
Inactive-state setup time also is referred to as recovery time.
switching characteristics (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
V
CC
= 5 V,
T
A
= 25°C
V
CC
=
4.5 V to 5.5 V
UNIT
(INPUT)
(OUTPUT)
MIN TYP MAX MIN MAX
f
max
100 140 100 MHz
t
PLH
CLK
QorQ
3.2 4.6 6.5 3.2 7.5
ns
t
PHL
CLK
Q
or
Q
3.2 6.1 8.5 3.2 9.5
ns
t
PLH
CLR
Q
3.2 6.1 8.5 3.2 9
ns
t
PHL
CLR
Q
3.7 8.6 11.5 3.7 13
ns