Datasheet
SCDS054I − MARCH 1998 − REVISED OCTOBER 2003
4
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP
†
MAX UNIT
V
IK
V
CC
= 3 V, I
I
= −18 mA −1.2 V
I
I
V
CC
= 3.6 V, V
I
= V
CC
or GND ±1 µA
I
off
V
CC
= 0, V
I
or V
O
= 0 to 3.6 V 20 µA
I
CC
V
CC
= 3.6 V, I
O
= 0, V
I
= V
CC
or GND 10 µA
∆I
CC
‡
Control inputs V
CC
= 3.6 V, One input at 3 V, Other inputs at V
CC
or GND 300 µA
C
i
Control inputs V
I
= 3 V or 0 3 pF
C
io(OFF)
A port
V
O
= 3 V or 0,
OE = V
CC
40.5
pF
C
io(OFF)
B port
V
O
= 3 V or 0,
OE = V
CC
6
pF
V
CC
= 2.3 V,
V
I
= 0
I
I
= 64 mA 5 8
V
CC
= 2.3 V,
TYP at V
CC
= 2.5 V
V
I
= 0
I
I
= 24 mA 5 8
r
on
§
TYP at V
CC
= 2.5 V
V
I
= 1.7 V, I
I
= 15 mA 27 40
Ω
r
on
§
V
I
= 0
I
I
= 64 mA 5 7
Ω
V
CC
= 3 V
V
I
= 0
I
I
= 24 mA 5 7
V
CC
= 3 V
V
I
= 2.4 V, I
I
= 15 mA 10 15
†
All typical values are at V
CC
= 3.3 V (unless otherwise noted), T
A
= 25°C.
‡
This is the increase in supply current for each input that is at the specified voltage level, rather than V
CC
or GND.
§
Measured by the voltage drop between the A and the B terminals at the indicated current through the switch. On-state resistance is determined
by the lower of the voltages of the two (A or B) terminals.
switching characteristics over recommended operating free-air temperature range (unless
otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
V
CC
= 2.5 V
± 0.2 V
V
CC
= 3.3 V
± 0.3 V
UNIT
PARAMETER
(INPUT)
(OUTPUT)
MIN MAX MIN MAX
UNIT
t
pd
A or B
¶
B or A 0.15 0.25
ns
t
pd
S A 1 6.1 1 5.3
ns
t
en
S
B 1 4.1 1 3.6 ns
t
dis
S
B 1 3.5 1 3.3 ns
t
en
OE
A or B 1 5.2 1 4.5 ns
t
dis
OE
A or B 1 6.7 1 7.2 ns
¶
The propagation delay is the calculated RC time constant of the typical on-state resistance of the switch and the specified load capacitance, when
driven by an ideal voltage source (zero output impedance).