Datasheet

www.ti.com
Electrical Characteristics
Switching Characteristics
SN74CBTLV1G125
LOW-VOLTAGE SINGLE FET BUS SWITCH
SCDS057H MARCH 1998 REVISED JUNE 2006
over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP
(1)
MAX UNIT
V
IK
V
CC
= 3 V, I
I
= –18 mA –1.2 V
I
I
V
CC
= 3.6 V, V
I
= V
CC
or GND ±1 µ A
I
off
V
CC
= 0, V
I
or V
O
= 0 to 3.6 V 10 µ A
I
CC
V
CC
= 3.6 V, I
O
= 0, V
I
= V
CC
or GND 10 µ A
I
CC
(2)
Control inputs V
CC
= 3.6 V, One input at 3 V, Other inputs at V
CC
or GND 300 µ A
C
i
Control inputs V
I
= 3 V or 0 2.5 pF
C
io(OFF)
V
O
= 3 V or 0, OE = V
CC
7 pF
I
I
= 64 mA 7 10
V
I
= 0
V
CC
= 2.3 V,
I
I
= 24 mA 7 10
TYP at V
CC
= 2.5 V
V
I
= 1.7 V, I
I
= 15 mA 15 25
r
on
(3)
I
I
= 64 mA 5 7
V
I
= 0
V
CC
= 3 V I
I
= 24 mA 5 7
V
I
= 2.4 V, I
I
= 15 mA 10 15
(1) All typical values are at V
CC
= 3.3 V (unless otherwise noted), T
A
= 25°C.
(2) This is the increase in supply current for each input that is at the specified TTL voltage level, rather than V
CC
or GND.
(3) Measured by the voltage drop between A and B terminals at the indicated current through the switch. On-state resistance is determined
by the lower of the voltages of the two (A or B) terminals.
over recommended operating free-air temperature range (unless otherwise noted) (see Figure 1 )
V
CC
= 2.5 V V
CC
= 3.3 V
FROM TO
± 0.2 V ± 0.3 V
PARAMETER UNIT
(INPUT) (OUTPUT)
MIN MAX MIN MAX
t
pd
(1)
A or B B or A 0.15 0.25 ns
t
en
OE A or B 1 4 1 4 ns
t
dis
OE A or B 1 5 1 4.1 ns
(1) The propagation delay is the calculated RC time constant of the typical on-state resistance of the switch and the specified load
capacitance of 50 pF, when driven by an ideal voltage source (zero output impedance).
3