Datasheet


      
      
SCDS140 − OCTOBER 2003
5
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP
MAX UNIT
V
IK
Control inputs V
CC
= 4.5 V, I
IN
= −18 mA −1.8 V
V
IKU
Data inputs V
CC
= 5 V,
0 mA > I
I
−50 mA,
V
IN
= V
CC
or GND,
Switch OFF −2 V
V
O(USP)
V
CC
= BIASV = 5 V,
I
I
= −10 mA,
V
IN
= V
CC
or GND,
Switch OFF 3 V
V
O
B port
V
CC
= 0 V, BIASV = V
x
, I
O
= 0 V
x
−0.1 V
x
V
I
IN
Control inputs V
CC
= 5.5 V, V
IN
= V
CC
or GND ±1 µA
I
O
B port V
CC
= 4.5 V,
BIASV = 2.4 V,
V
O
= 0,
Switch OFF,
V
IN
= V
CC
or GND
0.25 mA
I
OZ
§
V
CC
= 5.5 V,
V
O
= 0 to 5.5 V,
V
I
= 0,
Switch OFF,
V
IN
= V
CC
or GND
±10 µA
I
off
V
CC
= 0, V
O
= 0 to 5.5 V, V
I
= 0 10 µA
I
CC
V
CC
= 5.5 V,
I
I/O
= 0,
V
IN
= V
CC
or GND,
Switch ON or OFF 3 µA
I
CC
Control inputs V
CC
= 5.5 V, One input at 3.4 V, Other inputs at V
CC
or GND 2.5 mA
C
in
Control inputs V
IN
= 3 V or 0 4 pF
C
io(OFF)
A port V
I/O
= 3 V or 0, Switch OFF, V
IN
= V
CC
or GND 5.5 pF
C
io(ON)
V
I/O
= 3 V or 0, Switch ON, V
IN
= V
CC
or GND 13.5 pF
V
CC
= 4 V,
TYP at V
CC
= 4 V
V
I
= 2.4 V, I
O
= −15 mA 8 12
r
on
#
V
I
= 0
I
O
= 64 mA 3 6
r
on
#
V
CC
= 4.5 V
V
I
= 0
I
O
= 30 mA 3 6
V
CC
= 4.5 V
V
I
= 2.4 V, I
O
= −15 mA 5 10
V
IN
and I
IN
refer to control inputs. V
I
, V
O
, I
I
, and I
O
refer to data pins.
All typical values are at V
CC
= 5 V (unless otherwise noted), T
A
= 25°C.
V
O(USP)
= A-port undershoot static protection.
§
For I/O ports, the parameter I
OZ
includes the input leakage current.
This is the increase in supply current for each input that is at the specified voltage level, rather than V
CC
or GND.
#
Measured by the voltage drop between the A and B terminals at the indicated current through the switch. ON-state resistance is determined by
the lower of the voltages of the two (A or B) terminals.
switching characteristics over recommended operating free-air temperature range (unless
otherwise noted) (see Figure 1)
PARAMETER
TEST
CONDITIONS
FROM
(INPUT)
TO
(OUTPUT)
V
CC
= 4 V
V
CC
= 5 V
± 0.5 V
UNIT
PARAMETER
CONDITIONS
(INPUT)
(OUTPUT)
MIN MAX MIN MAX
UNIT
t
pd
||
A or B B or A 0.24 0.15 ns
t
PZH
BIASV = GND
OE
A or B
5.2 1.5 4.8
ns
t
PZL
BIASV = 3 V
OE
A or B
5.2 1.5 4.8
ns
t
PHZ
BIASV = GND
OE
A or B
4.9 1.5 5.3
ns
t
PLZ
BIASV = 3 V
OE
A or B
4.9 1.5 5.3
ns
||
The propagation delay is the calculated RC time constant of the typical ON-state resistance of the switch and the specified load capacitance,