Datasheet




SCBS059B − MARCH 1989 − REVISED NOVEMBER 1993
2−4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443
HOUSTON, TEXAS 77251−1443
FUNCTION TABLES
INPUTS
OUTPUTS
CONTROL SELECT
OUTPUTS
G 1G SD 1B 1A 1Y0 1Y1 1Y2 1Y3
H X X X X H H H H
X HXXXHHHH
X XLXXHHHH
L LHLLLHHH
L LHLHHLHH
L LHHLHHLH
L L H H H H H H L
INPUTS
OUTPUTS
CONTROL SELECT
OUTPUTS
G 2G SD 2B 2A 2Y0 2Y1 2Y2 2Y3
H X X X X H H H H
X HXXXHHHH
X XLXXHHHH
L HHL LLHHH
L HHLHHLHH
L HHHLHHLH
L H H H H H H H L
NOTE: For a 3-line to 8-line decoder, the following pins must
be shorted: 1G
to 2G, 1A to 2A and 1B to 2B.
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
bat
0.5 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Supply voltage range, V
CC
0.5 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Supply voltage V
CC
with respect to V
bat
1.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage range, V
I
0.5 V to V
CC
+ 0.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Off-state output voltage range at VS 0.5 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Voltage range applied to any Y output in the power-off state 0.5 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Voltage applied to any Y output in the power-off state with respect to V
bat
0.5 V. . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range 0°C to 70°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range 65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability