Datasheet

www.ti.com
ELECTRICAL CHARACTERISTICS
(1) (2)
SN74AVCBH164245
16-BIT DUAL-SUPPLY BUS TRANSCEIVER
WITH CONFIGURABLE VOLTAGE TRANSLATION AND 3-STATE OUTPUTS
SCES393B JUNE 2002 REVISED MARCH 2008
over operating free-air temperature range (unless otherwise noted)
PARAMETER TEST CONDITIONS V
CCA
V
CCB
MIN TYP
(3)
MAX UNIT
I
OH
= 100 µ A V
I
= V
IH
1.4 V to 3.6 V 1.4 V to 3.6 V V
CCO
0.2
I
OH
= 2 mA V
I
= V
IH
1.4 V 1.4 V 1.05
V
OH
I
OH
= 4 mA V
I
= V
IH
1.65 V 1.65 V 1.2 V
I
OH
= 8 mA V
I
= V
IH
2.3 V 2.3 V 1.75
I
OH
= 12 mA V
I
= V
IH
3 V 3 V 2.3
I
OH
= 100 µ A V
I
= V
IL
1.4 V to 3.6 V 1.4 V to 3.6 V 0.2
I
OH
= 2 mA V
I
= V
IL
1.4 V 1.4 V 0.35
V
OL
I
OH
= 4 mA V
I
= V
IL
1.65 V 1.65 V 0.45 V
I
OH
= 8 mA V
I
= V
IL
2.3 V 2.3 V 0.55
I
OH
= 12 mA V
I
= V
IL
3 V 3 V 0.7
I
I
Control inputs V
I
= V
CCB
or GND 1.4 V to 3.6 V 3.6 V ± 2.5 µ A
V
I
= 0.49 V 1.4 V 1.4 V 11
V
I
= 0.57 V 1.65 V 1.65 V 25
I
BHL
(4)
µ A
V
I
= 0.7 V 2.3 V 2.3 V 45
V
I
= 0.8 V 3 V 3 V 75
V
I
= 0.49 V 1.4 V 1.4 V 11
V
I
= 0.57 V 1.65 V 1.65 V 25
I
BHH
(5)
µ A
V
I
= 0.7 V 2.3 V 2.3 V 45
V
I
= 0.8 V 3 V 3 V 75
1.6 V 1.6 V 100
1.95 V 1.95 V 200
I
BHLO
(6)
V
I
= 0 to V
CC
µ A
2.7 V 2.7 V 300
3.6 V 3.6 V 525
1.6 V 1.6 V 100
1.95 V 1.95 V 200
I
BHHO
(7)
V
I
= 0 to V
CC
µ A
2.7 V 2.7 V 300
3.6 V 3.6 V 525
A port 0 V 0 to 3.6 V ± 10
I
off
V
I
or V
O
= 0 to 3.6 V µ A
B port 0 to 3.6 V 0 V ± 10
A or B ports OE = V
IH
3.6 V 3.6 V ± 12.5
V
O
= V
CCO
or GND,
I
OZ
(8)
B port 0 V 3.6 V ± 12.5 µ A
OE = don't
V
I
= V
CCI
or GND
care
A port 3.6 V 0 V ± 12.5
1.6 V 1.6 V 20
1.95 V 1.95 V 20
2.7 V 2.7 V 30
I
CCA
V
I
= V
CCI
or GND, I
O
= 0 µ A
0 V 3.6 V 40
3.6 V 0 V 40
3.6 V 3.6 V 40
(1) V
CCO
is the V
CC
associated with the output port.
(2) V
CCI
is the V
CC
associated with the input port.
(3) All typical values are at T
A
= 25 ° C.
(4) The bus-hold circuit can sink at least the minimum low sustaining current at VIL max. IBHL should be measured after lowering VIN to
GND and then raising it to VIL max.
(5) The bus-hold circuit can source at least the minimum high sustaining current at VIH min. IBHH should be measured after raising VIN to
VCC and then lowering it to VIH min.
(6) An external driver must source at least IBHLO to switch this node from low to high.
(7) An external driver must sink at least IBHHO to switch this node from high to low.
(8) For I/O ports, the parameter I
OZ
includes the input leakage current.
Copyright © 2002 2008, Texas Instruments Incorporated Submit Documentation Feedback 5
Product Folder Link(s): SN74AVCBH164245