Datasheet

RECOMMENDED OPERATING CONDITIONS
(1) (2) (3)
SN74AVC6T622
www.ti.com
............................................................................................................................................. SCES706A SEPTEMBER 2008 REVISED MARCH 2009
V
CCI
V
CCO
MIN MAX UNIT
V
CCA
Supply voltage 1.2 3.6 V
V
CCB
Supply voltage 1.2 3.6 V
1.2 V to 1.95 V V
CCI
× 0.65
V
IH
High-level input voltage All inputs
(4)
1.95 V to 2.7 V 1.7 V
2.7 V to 3.6 V 2
1.2 V to 1.95 V V
CCI
× 0.35
V
IL
Low-level input voltage All inputs
(4)
1.95 V to 2.7 V 0.7 V
2.7 V to 3.6 V 0.8
V
I
Input voltage Control inputs 0 3.6 V
Active state 0 V
CCO
V
I/O
Input/output voltage V
3-state 0 3.6
1.2 V 1
1.4 V to 1.6 V 1
I
OH
High-level output current (A port) 1.65 V to 1.95 V 2 mA
2.3 V to 2.7 V 4
3 V to 3.6 V 8
1.2 V 1
1.4 V to 1.6 V 1
I
OL
Low-level output current (A port) 1.65 V to 1.95 V 2 mA
2.3 V to 2.7 V 4
3 V to 3.6 V 8
1.2 V 1
1.4 V to 1.6 V 2
I
OH
High-level output current (B port) 1.65 V to 1.95 V 4 mA
2.3 V to 2.7 V 8
3 V to 3.6 V 16
1.2 V 1
1.4 V to 1.6 V 2
I
OL
Low-level output current (B port) 1.65 V to 1.95 V 4 mA
2.3 V to 2.7 V 8
3 V to 3.6 V 16
Δ t/ Δ v Input transition rise or fall rate 5 ns/V
T
A
Operating free-air temperature 40 85 ° C
(1) V
CCI
is the V
CC
associated with the input port.
(2) V
CCO
is the V
CC
associated with the output port.
(3) All unused data inputs of the device must be held at V
CCI
or GND to ensure proper device operation. Refer to the TI application report,
Implications of Slow or Floating CMOS Inputs, literature number SCBA004.
(4) DIR2, DIR1, and DIR(345) are referenced to V
CCA
.
Copyright © 2008 2009, Texas Instruments Incorporated Submit Documentation Feedback 7
Product Folder Link(s): SN74AVC6T622