Datasheet
www.ti.com
Electrical Characteristics
Timing Requirements
Switching Characteristics
SN74AVC16374
16-BIT EDGE-TRIGGERED D-TYPE FLIP-FLOP
WITH 3-STATE OUTPUTS
SCES158H – DECEMBER 1998 – REVISED MARCH 2005
over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER TEST CONDITIONS V
CC
MIN TYP
(1)
MAX UNIT
I
OHS
= –100 µ A 1.4 V to 3.6 V V
CC
– 0.2
I
OHS
= –2 mA, V
IH
= 0.91 V 1.4 V 1.05
V
OH
I
OHS
= –4 mA, V
IH
= 1.07 V 1.65 V 1.2 V
I
OHS
= –8 mA, V
IH
= 1.7 V 2.3 V 1.75
I
OHS
= –12 mA, V
IH
= 2 V 3 V 2.3
I
OLS
= 100 µ A 1.4 V to 3.6 V 0.2
I
OLS
= 2 mA, V
IL
= 0.49 V 1.4 V 0.4
V
OL
I
OLS
= 4 mA, V
IL
= 0.57 V 1.65 V 0.45 V
I
OLS
= 8 mA, V
IL
= 0.7 V 2.3 V 0.55
I
OLS
= 12 mA, V
IL
= 0.8 V 3 V 0.7
I
I
V
I
= V
CC
or GND 3.6 V ± 2.5 µ A
I
off
V
I
or V
O
= 3.6 V 0 ± 10 µ A
I
OZ
V
O
= V
CC
or GND 3.6 V ± 10 µ A
I
CC
V
I
= V
CC
or GND, I
O
= 0 3.6 V 40 µ A
2.5 V 3
Control inputs V
I
= V
CC
or GND
3.3 V 3
C
i
pF
2.5 V 2.5
Data inputs V
I
= V
CC
or GND
3.3 V 2.5
2.5 V 6.5
C
o
Outputs V
O
= V
CC
or GND pF
3.3 V 6.5
(1) Typical values are measured at V
CC
= 2.5 V and 3.3 V, T
A
= 25 ° C.
over recommended operating free-air temperature range (unless otherwise noted)
V
CC
= 1.5 V V
CC
= 1.8 V V
CC
= 2.5 V V
CC
= 3.3 V
V
CC
= 1.2 V
± 0.1 V ± 0.15 V ± 0.2 V ± 0.3 V
UNIT
MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX
f
clock
Clock frequency 160 200 200 MHz
t
w
Pulse duration, CLK high or low 3.1 2.5 2.5 ns
t
su
Setup time, data before CLK ↑ 4.1 2.7 1.9 1.4 1.4 ns
t
h
Hold time, data after CLK ↑ 1.7 1.3 1.2 1.1 1.1 ns
over recommended operating free-air temperature range (unless otherwise noted) (see Figure 2 through Figure 5 )
V
CC
= 1.5 V V
CC
= 1.8 V V
CC
= 2.5 V V
CC
= 3.3 V
V
CC
= 1.2 V
FROM TO
± 0.1 V ± 0.15 V ± 0.2 V ± 0.3 V
PARAMETER UNIT
(INPUT) (OUTPUT)
TYP MIN MAX MIN MAX MIN MAX MIN MAX
f
max
160 200 200 MHz
t
pd
CLK Q 7.3 1.5 8.4 1.2 6.7 0.8 4.1 0.7 3.3 ns
t
en
OE Q 7.4 1.6 8.5 1.6 6.7 0.9 4.3 0.7 3.4 ns
t
dis
OE Q 8.4 2.5 9.4 2.3 7.8 1 4.2 1.5 3.9 ns
7