Datasheet

SN74AUP2G08
SCES681D JANUARY 2008REVISED OCTOBER 2010
www.ti.com
SWITCHING CHARACTERISTICS
over recommended operating free-air temperature range, C
L
= 5 pF (unless otherwise noted) (see Figure 3 and Figure 4)
T
A
= 25°C T
A
= –40°C to 85°C
FROM TO
PARAMETER V
CC
UNIT
(INPUT) (OUTPUT)
MIN TYP MAX MIN MAX
0.8 V 19.8
1.2 V ± 0.1 V 0.5 7.8 18.8 0.5 19.8
1.5 V ± 0.1 V 0.5 5.4 11.8 0.5 13.9
t
pd
A or B Y ns
1.8 V ± 0.15 V 0.5 4.3 9 0.5 11.1
2.5 V ± 0.2 V 0.5 3 5.7 0.5 7.8
3.3 V ± 0.3 V 0.5 2.4 4.6 0.5 5.9
SWITCHING CHARACTERISTICS
over recommended operating free-air temperature range, C
L
= 10 pF (unless otherwise noted) (see Figure 3 and Figure 4)
T
A
= 25°C T
A
= –40°C to 85°C
FROM TO
PARAMETER V
CC
UNIT
(INPUT) (OUTPUT)
MIN TYP MAX MIN MAX
0.8 V 23.1
1.2 V ± 0.1 V 0.5 8.9 21.1 0.5 22
1.5 V ± 0.1 V 0.8 6.3 13.2 0.5 15.1
t
pd
A or B Y ns
1.8 V ± 0.15 V 0.6 5 10.1 0.5 12.2
2.5 V ± 0.2 V 0.5 3.6 7.4 0.5 9
3.3 V ± 0.3 V 0.5 2.9 5.1 0.5 6.5
6 Submit Documentation Feedback Copyright © 2008–2010, Texas Instruments Incorporated
Product Folder Link(s): SN74AUP2G08