RECOMMENDED OPERATING CONDITIONS
VCCA VCCB MIN MAX UNIT
V
CCA
,
Supply voltage 0.9 3.6 V
V
CCB
0.9 to 1.95V 0.9 to 1.95V 0.65 x V
CCA
V
IH
High-level input voltage 2.3 to 2.7V 0.9 to 3.6V 1.6 V
3.0 to 3.6V 0.9 to 3.6V 2
0.9 V 0.9 to 1.95V 0.3 x V
CCA
1 to 1.95V 0.9 to 1.95V 0.35 x V
CCA
V
IL
Low-level input voltage V
2.3 to 2.7V 0.9 to 3.6V 0.7
3.0 to 3.6V 0.9 to 3.6V 0.9
Δt/Δv Input transition rise or fall rate 3.0 to 3.6V 0.9 to 3.6V 200 ns/V
T
A
Operating free-air temperature –40 85 °C
RECOMMENDED OPERATING CONDITIONS
over operating free-air temperature range (unless otherwise noted)
PARAMETER TEST CONDITIONS VCCA VCCB MIN MAX UNIT
I
OH
= –100 µA 0.9 V to 3.6 V 0.9 V to 3.6 V VCCB – 0.2
I
OH
= –0.25 mA 0.9 V 1V 0.9 V 1V 0.75 x VCCB
I
OH
= –1.5 mA 1.2 V 1.2 V 1.0
V
OH
V
I
= V
IH
V
I
OH
= –2 mA 1.65 V 1.65 V 1.32
I
OH
= –3 mA 2.3 V 2.3 V 1.9
I
OH
= –6 mA 3 V 3 V 2.72
I
OL
= 100 µA 0.9 V to 3.6 V 0.9 V to 3.6 V 0.1
I
OL
= 0.25 mA 0.9 V 1V 0.9 V 1V 0.1
I
OL
= 1.5 mA 1.2 V 1.2 V 0.3 x VCCB
V
OL
V
I
= V
IL
V
I
OL
= 2 mA 1.65 V 1.65 V 0.31
I
OL
= 3 mA 2.3 V 2.3 V 0.31
I
OL
= 6 mA 3 V 3 V 0.31
I
I
Control inputs V
I
= VCCA or GND 0.9 V to 3.6 V 0.9 V to 3.6 V ±1 µA
0 V 0 V to 3.6 V ±5
I
off
A or B port VI or VO = 0 to 3.6 V µA
0 V to 3.6 V 0 V ±5
0.9 V to 3.6 V 0.9 V to 3.6 V 5
0.9 V to 3.6 V VCCA 2
I
CCA
VI = VCCI or GND, IO = 0 µA
0 V 0 V to 3.6 V 1
0 V to 3.6 V 0 V 1
0.9 V to 3.6 V 0.9 V to 3.6 V 5
0.9 V to 3.6 V VCCA 2
I
CCB
VI = VCCI or GND, IO = 0 µA
0 V 0 V to 3.6 V 1
0 V to 3.6 V 0 V 1
I
CCA
+ I
CCB
VI = VCCI or GND, IO = 0 0.9 V to 3.6 V 0.9 V to 3.6 V 5.2 µA
C
i
Control inputs VI = 3.3 V or GND 3.3 V 3.3 V 4 pF
C
io
A or B port VO = 3.3 V or GND 0 V 3.3 V 7 pF
Copyright © 2012–2013, Texas Instruments Incorporated Submit Documentation Feedback 3
Product Folder Links: SN74AUP1T34