Datasheet
SN74AUP1G98
SCES506H –NOVEMBER 2003–REVISED MAY 2010
www.ti.com
SWITCHING CHARACTERISTICS
over recommended operating free-air temperature range, C
L
= 5 pF (unless otherwise noted) (see Figure 10 and Figure 11)
T
A
= –40°C
T
A
= 25°C
FROM TO
to 85°C
PARAMETER V
CC
UNIT
(INPUT) (OUTPUT)
MIN TYP MAX MIN MAX
0.8 V 22.2
1.2 V ± 0.1 V 2.7 9.1 13.6 2.2 17
1.5 V ± 0.1 V 2 6.4 9.2 1.5 11.1
t
pd
A, B, or C Y ns
1.8 V ± 0.15 V 1.4 5.2 7.2 0.9 8.9
2.5 V ± 0.2 V 1.2 3.8 5.3 0.7 6.3
3.3 V ± 0.3 V 1 3.1 4.5 0.5 5.3
SWITCHING CHARACTERISTICS
over recommended operating free-air temperature range, C
L
= 10 pF (unless otherwise noted) (see Figure 10 and Figure 11)
T
A
= –40°C
T
A
= 25°C
FROM TO
to 85°C
PARAMETER V
CC
UNIT
(INPUT) (OUTPUT)
MIN TYP MAX MIN MAX
0.8 V 25.4
1.2 V ± 0.1 V 5.2 10.4 15.4 4.7 19
1.5 V ± 0.1 V 4 7.4 10.5 3.5 12.6
t
pd
A, B, or C Y ns
1.8 V ± 0.15 V 3.1 6 8.3 2.6 10.2
2.5 V ± 0.2 V 2.7 4.5 6.1 2.2 7.3
3.3 V ± 0.3 V 2.5 3.7 5 2 6
SWITCHING CHARACTERISTICS
over recommended operating free-air temperature range, C
L
= 15 pF (unless otherwise noted) (see Figure 10 and Figure 11)
T
A
= –40°C
T
A
= 25°C
FROM TO
to 85°C
PARAMETER V
CC
UNIT
(INPUT) (OUTPUT)
MIN TYP MAX MIN MAX
0.8 V 28.7
1.2 V ± 0.1 V 3.7 11.5 17 3.2 21.1
1.5 V ± 0.1 V 2.8 8.3 11.6 2.3 14
t
pd
A, B, or C Y ns
1.8 V ± 0.15 V 2.1 6.7 9.2 1.6 11.3
2.5 V ± 0.2 V 1.8 5 6.7 1.3 8.1
3.3 V ± 0.3 V 1.6 4.1 5.5 1.1 6.6
SWITCHING CHARACTERISTICS
over recommended operating free-air temperature range, C
L
= 30 pF (unless otherwise noted) (see Figure 10 and Figure 11)
T
A
= –40°C
T
A
= 25°C
FROM TO
to 85°C
PARAMETER V
CC
UNIT
(INPUT) (OUTPUT)
MIN TYP MAX MIN MAX
0.8 V 39.7
1.2 V ± 0.1 V 5.1 15.3 21.6 4.6 26.8
1.5 V ± 0.1 V 3.9 10.9 14.6 3.4 17.6
t
pd
A, B, or C Y ns
1.8 V ± 0.15 V 3.1 8.9 11.5 2.6 14.1
2.5 V ± 0.2 V 2.6 6.7 8.4 2.1 10.1
3.3 V ± 0.3 V 2.3 5.5 6.9 1.8 8.3
8 Submit Documentation Feedback Copyright © 2003–2010, Texas Instruments Incorporated