Datasheet

SN74AUP1G80
SCES593E JULY 2004REVISED MAY 2010
www.ti.com
TIMING REQUIREMENTS
over recommended operating free-air temperature range (unless otherwise noted) (see Figure 3)
T
A
= –40°C
T
A
= 25°C
to 85°C
V
CC
UNIT
TYP MIN MAX
0.8 V 20
1.2 V ± 0.1 V 80
1.5 V ± 0.1 V 120
f
clock
Clock frequency MHz
1.8 V ± 0.15 V 160
2.5 V ± 0.2 V 220
3.3 V ± 0.3 V 260
0.8 V 5.5
1.2 V ± 0.1 V 2.5
1.5 V ± 0.1 V 1.5
t
w
Pulse duration, CLK high or low
1.8 V ± 0.15 V 1.6
2.5 V ± 0.2 V 1.7
3.3 V ± 0.3 V 1.9
0.8 V 3.4 6.7
1.2 V ± 0.1 V 2.4
1.5 V ± 0.1 V 1.2
Data high ns
1.8 V ± 0.15 V 0.8
2.5 V ± 0.2 V 0.6
3.3 V ± 0.3 V 0.4
t
su
Setup time before CLK
0.8 V 3.4 8.9
1.2 V ± 0.1 V 2
1.5 V ± 0.1 V 1.3
Data low ns
1.8 V ± 0.15 V 1.1
2.5 V ± 0.2 V 0.8
3.3 V ± 0.3 V 0.7
0.8 V 0 1
1.2 V ± 0.1 V 0
1.5 V ± 0.1 V 0
t
h
Hold time, data after CLK ns
1.8 V ± 0.15 V 0
2.5 V ± 0.2 V 0
3.3 V ± 0.3 V 0
6 Submit Documentation Feedback Copyright © 2004–2010, Texas Instruments Incorporated
Product Folder Link(s): SN74AUP1G80