Datasheet

SN74AUP1G79
SCES592G JULY 2004REVISED MAY 2010
www.ti.com
SWITCHING CHARACTERISTICS
over recommended operating free-air temperature range, C
L
= 15 pF (unless otherwise noted) (see Figure 3 and Figure 4)
T
A
= –40°C
T
A
= 25°C
FROM TO
to 85°C
PARAMETER V
CC
UNIT
(INPUT) (OUTPUT)
MIN TYP MAX MIN MAX
0.8 V 48 30
1.2 V ± 0.1 V 112 120
1.5 V ± 0.1 V 151 160
f
max
MHz
1.8 V ± 0.15 V 194 220
2.5 V ± 0.2 V 248 250
3.3 V ± 0.3 V 280 260
0.8 V 20.3
1.2 V ± 0.1 V 5 8.7 13.6 3.9 15.6
1.5 V ± 0.1 V 4.1 6.3 9.3 3.1 10.7
t
pd
CLK Q ns
1.8 V ± 0.15 V 3.3 4 7.6 2.4 8.7
2.5 V ± 0.2 V 2.6 3.6 5.5 1.9 6.3
3.3 V ± 0.3 V 2.2 3 4.5 1.6 5
SWITCHING CHARACTERISTICS
over recommended operating free-air temperature range, C
L
= 30 pF (unless otherwise noted) (see Figure 3 and Figure 4)
T
A
= –40°C
T
A
= 25°C
FROM TO
to 85°C
PARAMETER V
CC
UNIT
(INPUT) (OUTPUT)
MIN TYP MAX MIN MAX
0.8 V 24 20
1.2 V ± 0.1 V 72 80
1.5 V ± 0.1 V 100 100
f
max
MHz
1.8 V ± 0.15 V 127 140
2.5 V ± 0.2 V 185 210
3.3 V ± 0.3 V 266 260
0.8 V 27.2
1.2 V ± 0.1 V 7 11.5 17.3 5.9 24
1.5 V ± 0.1 V 5.7 8.3 11.8 4.6 15.9
t
pd
CLK Q ns
1.8 V ± 0.15 V 4.7 6.7 9.6 3.8 13
2.5 V ± 0.2 V 3.7 4.9 7 2.9 9
3.3 V ± 0.3 V 3.2 4.1 5.8 2.6 7.2
OPERATING CHARACTERISTICS
T
A
= 25°C
PARAMETER TEST CONDITIONS V
CC
TYP UNIT
0.8 V 2.5
1.2 V ± 0.1 V 2.5
1.5 V ± 0.1 V 2.5
C
pd
Power dissipation capacitance f = 10 MHz pF
1.8 V ± 0.15 V 2.5
2.5 V ± 0.2 V 3
3.3 V ± 0.3 V 3
8 Submit Documentation Feedback Copyright © 2004–2010, Texas Instruments Incorporated
Product Folder Link(s): SN74AUP1G79