Datasheet

SN74AUP1G57
SCES503I NOVEMBER 2003REVISED MAY 2010
www.ti.com
SWITCHING CHARACTERISTICS
over recommended operating free-air temperature range, C
L
= 5 pF (unless otherwise noted) (see Figure 6 and Figure 7)
T
A
= 25°C T
A
= –40°C to 85°C
FROM TO
PARAMETER V
CC
UNIT
(INPUT) (OUTPUT)
MIN TYP MAX MIN MAX
0.8 V 28.6
1.2 V ± 0.1 V 2.6 9.5 13.6 2.1 17.1
1.5 V ± 0.1 V 1.9 6.4 9.1 1.4 11.1
t
pd
In0, In1, or In2 Y ns
1.8 V ± 0.15 V 1.4 5.2 7.1 0.9 8.9
2.5 V ± 0.2 V 1.1 3.6 5.3 0.6 6.3
3.3 V ± 0.3 V 1 2.9 4.4 0.5 5.3
SWITCHING CHARACTERISTICS
over recommended operating free-air temperature range, C
L
= 10 pF (unless otherwise noted) (see Figure 6 and Figure 7)
T
A
= 25°C T
A
= –40°C to 85°C
FROM TO
PARAMETER V
CC
UNIT
(INPUT) (OUTPUT)
MIN TYP MAX MIN MAX
0.8 V 32.8
1.2 V ± 0.1 V 2.6 11 15.1 2.1 18.1
1.5 V ± 0.1 V 1.9 7.4 10.3 1.4 12.4
t
pd
In0, In1, or In2 Y ns
1.8 V ± 0.15 V 1.4 6 8.1 0.9 10
2.5 V ± 0.2 V 1.1 4.3 6.1 0.6 7.3
3.3 V ± 0.3 V 1 3.5 5.1 0.5 6.1
SWITCHING CHARACTERISTICS
over recommended operating free-air temperature range, C
L
= 15 pF (unless otherwise noted) (see Figure 6 and Figure 7)
T
A
= 25°C T
A
= –40°C to 85°C
FROM TO
PARAMETER V
CC
UNIT
(INPUT) (OUTPUT)
MIN TYP MAX MIN MAX
0.8 V 37
1.2 V ± 0.1 V 3.6 12.3 16.8 3.1 20.1
1.5 V ± 0.1 V 2.8 8.3 11.4 2.3 13.7
t
pd
In0, In1, or In2 Y ns
1.8 V ± 0.15 V 2.1 6.7 9 1.6 11.1
2.5 V ± 0.2 V 1.7 4.9 6.8 1.2 8.1
3.3 V ± 0.3 V 1.5 3.9 5.6 1 6.7
SWITCHING CHARACTERISTICS
over recommended operating free-air temperature range, C
L
= 30 pF (unless otherwise noted) (see Figure 6 and Figure 7)
T
A
= 25°C T
A
= –40°C to 85°C
FROM TO
PARAMETER V
CC
UNIT
(INPUT) (OUTPUT)
MIN TYP MAX MIN MAX
0.8 V 49.3
1.2 V ± 0.1 V 5 15.7 21.4 4.5 26.5
1.5 V ± 0.1 V 3.9 10.8 14.4 3.4 17.4
t
pd
In0, In1, or In2 Y ns
1.8 V ± 0.15 V 3.1 8.8 11.4 2.6 14
2.5 V ± 0.2 V 2.6 6.4 8.4 2.1 10.1
3.3 V ± 0.3 V 2.3 5.3 7 1.8 8.4
6 Submit Documentation Feedback Copyright © 2003–2010, Texas Instruments Incorporated
Product Folder Link(s): SN74AUP1G57