Datasheet
SN74AUP1G14
www.ti.com
SCES578I –JUNE 2003–REVISED MAY 2010
SWITCHING CHARACTERISTICS
over recommended operating free-air temperature range, C
L
= 5 pF (unless otherwise noted) (see Figure 3 and Figure 4)
T
A
= –40°C
T
A
= 25°C
FROM TO
to 85°C
PARAMETER V
CC
UNIT
(INPUT) (OUTPUT)
MIN TYP MAX MIN MAX
0.8 V 16.3
1.2 V ± 0.1 V 4.2 6.9 11.7 0.9 15
1.5 V ± 0.1 V 3.7 5.2 8.4 1.7 10.7
t
pd
A Y ns
1.8 V ± 0.15 V 3.3 4.4 6.9 1.9 8.5
2.5 V ± 0.2 V 2.8 3.5 4.8 1.8 6.1
3.3 V ± 0.3 V 2.5 3 4 1.7 4.9
SWITCHING CHARACTERISTICS
over recommended operating free-air temperature range, C
L
= 10 pF (unless otherwise noted) (see Figure 3 and Figure 4)
T
A
= –40°C
T
A
= 25°C
FROM TO
to 85°C
PARAMETER V
CC
UNIT
(INPUT) (OUTPUT)
MIN TYP MAX MIN MAX
0.8 V 18.4
1.2 V ± 0.1 V 4.6 7.9 13.4 1.3 16.7
1.5 V ± 0.1 V 4 6 9.6 2.2 11.8
t
pd
A Y ns
1.8 V ± 0.15 V 3.6 5 7.9 2.4 9.5
2.5 V ± 0.2 V 3.2 4 5.5 2.3 6.8
3.3 V ± 0.3 V 2.9 3.5 4.6 2.1 5.6
SWITCHING CHARACTERISTICS
over recommended operating free-air temperature range, C
L
= 15 pF (unless otherwise noted) (see Figure 3 and Figure 4)
T
A
= –40°C
T
A
= 25°C
FROM TO
to 85°C
PARAMETER V
CC
UNIT
(INPUT) (OUTPUT)
MIN TYP MAX MIN MAX
0.8 V 20.1
1.2 V ± 0.1 V 5.5 8.7 14 2.5 17.3
1.5 V ± 0.1 V 4.7 6.7 10 3 12.5
t
pd
A Y ns
1.8 V ± 0.15 V 4.2 5.6 8.3 3 10.1
2.5 V ± 0.2 V 3.6 4.5 5.9 2.7 7.4
3.3 V ± 0.3 V 3.3 3.9 5 2.5 6.1
Copyright © 2003–2010, Texas Instruments Incorporated Submit Documentation Feedback 5
Product Folder Link(s): SN74AUP1G14