Datasheet

SN74AUP1G06
www.ti.com
SCES590D JULY 2004REVISED MAY 2010
SWITCHING CHARACTERISTICS
over recommended operating free-air temperature range, C
L
= 5 pF (unless otherwise noted) (see Figure 3 and Figure 4)
T
A
= –40°C
T
A
= 25°C
FROM TO
to 85°C
PARAMETER V
CC
UNIT
(INPUT) (OUTPUT)
MIN TYP MAX MIN MAX
0.8 V 12.4
1.2 V ± 0.1 V 2.7 12 9.9 2 12.8
1.5 V ± 0.1 V 2.1 3.5 6.2 1.5 7.6
t
pd
A Y ns
1.8 V ± 0.15 V 2.1 3.1 4.7 1.2 5.9
2.5 V ± 0.2 V 1.4 2.2 3.2 1 3.9
3.3 V ± 0.3 V 1.3 2.2 3.3 0.8 3.6
SWITCHING CHARACTERISTICS
over recommended operating free-air temperature range, C
L
= 10 pF (unless otherwise noted) (see Figure 3 and Figure 4)
T
A
= –40°C
T
A
= 25°C
FROM TO
to 85°C
PARAMETER V
CC
UNIT
(INPUT) (OUTPUT)
MIN TYP MAX MIN MAX
0.8 V 15.1
1.2 V ± 0.1 V 3.6 12 11.2 2.7 14.1
1.5 V ± 0.1 V 2.9 4.3 7 2.2 8.6
t
pd
A Y ns
1.8 V ± 0.15 V 2.7 3.9 5.4 1.8 6.7
2.5 V ± 0.2 V 2.1 2.9 3.8 1.4 4.5
3.3 V ± 0.3 V 1.7 3 4.5 1.2 4.9
SWITCHING CHARACTERISTICS
over recommended operating free-air temperature range, C
L
= 15 pF (unless otherwise noted) (see Figure 3 and Figure 4)
T
A
= –40°C
T
A
= 25°C
FROM TO
to 85°C
PARAMETER V
CC
UNIT
(INPUT) (OUTPUT)
MIN TYP MAX MIN MAX
0.8 V 17.4
1.2 V ± 0.1 V 4.9 12 12.2 3.4 15.2
1.5 V ± 0.1 V 3.5 5 7.7 2.7 9.4
t
pd
A Y ns
1.8 V ± 0.15 V 3.2 4.8 6.6 2.2 7.3
2.5 V ± 0.2 V 2.5 3.5 4.5 1.7 5.1
3.3 V ± 0.3 V 2 3.8 6 1.5 6.5
SWITCHING CHARACTERISTICS
over recommended operating free-air temperature range, C
L
= 30 pF (unless otherwise noted) (see Figure 3 and Figure 4)
T
A
= –40°C
T
A
= 25°C
FROM TO
to 85°C
PARAMETER V
CC
UNIT
(INPUT) (OUTPUT)
MIN TYP MAX MIN MAX
0.8 V 25.3
1.2 V ± 0.1 V 7.6 12 16 5.6 19.3
1.5 V ± 0.1 V 5.9 7.6 10.1 4.3 12
t
pd
A Y ns
1.8 V ± 0.15 V 4.8 7.4 10.7 3.6 11
2.5 V ± 0.2 V 3.7 5.4 7.1 2.8 7.8
3.3 V ± 0.3 V 3.2 6.5 10.5 2.5 10.8
Copyright © 2004–2010, Texas Instruments Incorporated Submit Documentation Feedback 5
Product Folder Links: SN74AUP1G06