Datasheet
Absolute Maximum Ratings
(1)
Recommended Operating Conditions
(1)
Electrical Characteristics
SN74AUC2G53
www.ti.com
................................................................................................................................................ SCES484C – AUGUST 2003 – REVISED JANUARY 2009
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
CC
Supply voltage range
(2)
– 0.5 3.6 V
V
I
Input voltage range
(2) (3)
– 0.5 3.6 V
V
I/O
Switch I/O voltage range
(2) (3)
– 0.5 V
CC
+ 0.5 V
I
IK
Control input clamp current V
I
< 0 – 50 mA
I
I/OK
I/O port diode current V
I/O
< 0 or V
I/O
> V
CC
50 mA
I
T
On-state switch current current V
I/O
= 0 to V
CC
50 mA
Continuous current through V
CC
or GND 100 mA
DCT package 220
θ
JA
Package thermal impedance
(4)
DCU package 227 C/W
YZP package 102
T
stg
Storage temperature range – 65 150 C
(1) Stresses beyond those listed under " absolute maximum ratings " may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under " recommended operating
conditions " is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltages are with respect to ground unless otherwise specified.
(3) The input negative-voltage and output voltage ratings may be exceeded if the input and output current ratings are observed.
(4) The package thermal impedance is calculated in accordance with JESD 51-7.
MIN MAX UNIT
V
CC
Supply voltage 0.8 2.7 V
V
CC
= 0.8 V V
CC
V
IH
High-level input voltage V
CC
= 1.1 V to 1.95 V 0.65 נ V
CC
V
V
CC
= 2.3 V to 2.7 V 1.7
V
CC
= 0.8 V 0
V
IL
Low-level input voltage V
CC
= 1.1 V to 1.95 V 0.35 נ V
CC
V
V
CC
= 2.3 V to 2.7 V 0.7
V
I/O
I/O port voltage 0 V
CC
V
V
I
Control input voltage 0 3.6 V
V
CC
= 0.8 V to 1.6 V 20
Δ t/ Δ v Input transition rise or fall rate V
CC
= 1.65 V to 1.95 V 10 ns/V
V
CC
= 2.3 V to 2.7 V 3.5
T
A
Operating free-air temperature – 40 85 C
(1) All unused inputs of the device must be held at V
CC
or GND to ensure proper device operation. Refer to the TI application report,
Implications of Slow or Floating CMOS Inputs, literature number SCBA004.
over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER TEST CONDITIONS V
CC
MIN TYP
(1)
MAX UNIT
V
I
= V
CC
or GND, 1.1 V 40
I
S
= 4 mA
V
INH
= V
IL
1.65 V 12.5 20
r
on
On-state switch resistance Ω
(see Figure 1 and
I
S
= 8 mA 2.3 V 6 15
Figure 2 )
V
I
= V
CC
to GND, 1.1 V 131 180
I
S
= 4 mA
V
INH
= V
IL
1.65 V 32 80
r
on(p)
Peak on resistance Ω
(see Figure 1 and
I
S
= 8 mA 2.3 V 15 20
Figure 2 )
(1) T
A
= 25C
Copyright © 2003 – 2009, Texas Instruments Incorporated Submit Documentation Feedback 3