Datasheet
SN74AUC2G04
DUAL INVERTER GATE
SCES437A – APRIL 2003 – REVISED JUNE 2003
4
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
switching characteristics over recommended operating free-air temperature range, C
L
= 15 pF
(unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
V
CC
= 0.8 V
V
CC
= 1.2 V
± 0.1 V
V
CC
= 1.5 V
± 0.1 V
V
CC
= 1.8 V
± 0.15 V
V
CC
= 2.5 V
± 0.2 V
UNIT
PARAMETER
(INPUT)
(OUTPUT)
TYP MIN MAX MIN MAX MIN TYP MAX MIN MAX
UNIT
t
pd
A
Y
5.4 0.9 3.1 0.7 2 0.6 1 1.7 0.5 1.2 ns
switching characteristics over recommended operating free-air temperature range, C
L
= 30 pF
(unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
V
CC
= 1.8 V
± 0.15 V
V
CC
= 2.5 V
± 0.2 V
UNIT
PARAMETER
(INPUT)
(OUTPUT)
MIN TYP MAX MIN MAX
UNIT
t
pd
A
Y
0.8 1.3 2 0.7 1.5 ns
operating characteristics, T
A
= 25°C
PARAMETER
TEST
V
CC
= 0.8 V V
CC
= 1.2 V V
CC
= 1.5 V V
CC
= 1.8 V V
CC
= 2.5 V
UNIT
PARAMETER
TEST
CONDITIONS
TYP TYP TYP TYP TYP
UNIT
C
pd
Power dissipation
capacitance
f = 10 MHz 12.5 12.5 12.5 12.5 14 pF