Datasheet
www.ti.com
1
2
7
1A
1B
1Y
5
6
3
2A
2B
2Y
Absolute Maximum Ratings
(1)
SN74AUC2G00
DUAL 2-INPUT POSITIVE-NAND GATE
SCES440C – MAY 2003 – REVISED JANUARY 2007
FUNCTION TABLE
(EACH GATE)
INPUTS
OUTPUT
Y
A B
H H L
L X H
X L H
LOGIC DIAGRAM (POSITIVE LOGIC)
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
CC
Supply voltage range –0.5 3.6 V
V
I
Input voltage range
(2)
–0.5 3.6 V
V
O
Voltage range applied to any output in the high-impedance or power-off state
(2)
–0.5 3.6 V
V
O
Output voltage range
(2)
–0.5 V
CC
+ 0.5 V
I
IK
Input clamp current V
I
< 0 –50 mA
I
OK
Output clamp current V
O
< 0 –50 mA
I
O
Continuous output current ± 20 mA
Continuous current through V
CC
or GND ± 100 mA
DCT package 220
θ
JA
Package thermal impedance
(3)
DCU package 227 ° C/W
YZP package 102
T
stg
Storage temperature range –65 150 ° C
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) The input negative-voltage and output voltage ratings may be exceeded if the input and output current ratings are observed.
(3) The package thermal impedance is calculated in accordance with JESD 51-7.
2