Datasheet

SN54ALS174, SN54ALS175, SN54AS174, SN54AS175B
SN74ALS174, SN74ALS175, SN74AS174, SN74AS175B
HEX/QUADRUPLE D-TYPE FLIP-FLOPS WITH CLEAR
SDAS207E - APRIL 1982 - REVISED MAY 2002
6
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
timing requirements over recommended operating free-air temperature range (unless otherwise
noted)
SN54AS174
SN54AS175B
SN74AS174
SN74AS175B
UNIT
MIN MAX MIN MAX
f
clock
* Clock frequency 100 100 MHz
CLR low
5.5 5
*
Pulse duration
CLK high
4 4
ns
w
Pulse
duration
CLK low
AS174 6 6
ns
CLK low
AS175B 5 5
Data
AS174 4 4
t
su
* Setup time before CLK
Data
AS175B 3 3
ns
CLR inactive 6 6
t
h
* Hold time, data after CLK 1 1 ns
* On products compliant to MIL-STD-883, Class B, this parameter is based on characterization data, but is not production tested.
switching characteristics (see Figure 1)
PARAMETER
FROM
(
INPUT
)
TO
(
OUTPUT
)
V
CC
= 4.5 V to 5.5 V,
C
L
= 50 pF,
R
L
= 500 ,
T
A
= MIN to MAX
UNIT
(INPUT)
(OUTPUT)
SN54AS174 SN74AS174
MIN MAX MIN MAX
f
max
* 100 100 MHz
t
PHL
CLR
Any Q 5 15 5 14 ns
t
PLH
CLK
Any Q
3.5 9.5 3.5 8
ns
t
PHL
CLK
Any
Q
4.5 11.5 4.5 10
ns
* On products compliant to MIL-STD-883, Class B, this parameter is based on characterization data, but is not production tested.
For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
switching characteristics (see Figure 1)
PARAMETER
FROM
(
INPUT
)
TO
(
OUTPUT
)
V
CC
= 4.5 V to 5.5 V,
C
L
= 50 pF,
R
L
= 500 ,
T
A
= MIN to MAX
UNIT
(INPUT)
(OUTPUT)
SN54AS175B SN74AS175B
MIN MAX MIN MAX
f
max
* 100 100 MHz
t
PLH
CLR
AQQ
4 10 4 9
ns
t
PHL
CLR
A
ny
Q
or
Q
4.5 15 4.5 13
ns
t
PLH
CLK
AnyQorQ
3 8.5 3 7.5
ns
t
PHL
CLK
A
ny
Q
or
Q
3 11 3 10
ns
* On products compliant to MIL-STD-883, Class B, this parameter is based on characterization data, but is not production tested.
For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.