Datasheet
SN74ALVC162836
20-BIT UNIVERSAL BUS DRIVER
WITH 3-STATE OUTPUTS
SCES129B – MARCH 1998 – REVISED FEBRUARY 1999
4–233
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER TEST CONDITIONS
V
CC
MIN TYP
†
MAX UNIT
I
OH
= –100 µA 1.65 V to 3.6 V V
CC
–0.2
I
OH
= –2 mA 1.65 V 1.2
I
OH
= –4 mA 2.3 V 1.9
V
OH
2.3 V 1.7
V
I
OH
= –6 mA
3 V 2.4
I
OH
= –8 mA 2.7 V 2
I
OH
= –12 mA 3 V 2
I
OL
= 100 µA 1.65 V to 3.6 V 0.2
I
OL
= 2 mA 1.65 V 0.45
I
OL
= 4 mA 2.3 V 0.4
V
OL
2.3 V 0.55
V
I
OL
= 6 mA
3 V 0.55
I
OL
= 8 mA 2.7 V 0.6
I
OL
= 12 mA 3 V 0.8
I
I
V
I
= V
CC
or GND 3.6 V ±5 µA
I
OZ
V
O
= V
CC
or GND 3.6 V ±10 µA
I
CC
V
I
= V
CC
or GND, I
O
= 0 3.6 V 40 µA
∆I
CC
One input at V
CC
– 0.6 V, Other inputs at V
CC
or GND 3 V to 3.6 V 750 µA
Control inputs 5
C
i
Data inputs
V
I
= V
CC
or GND 3.3 V
5.5
pF
C
o
Outputs V
O
= V
CC
or GND 3.3 V 7.5 pF
†
All typical values are at V
CC
= 3.3 V, T
A
= 25°C.
timing requirements over recommended operating free-air temperature range (unless otherwise
noted) (see Figures 1 through 3)
V
CC
= 1.8 V
V
CC
= 2.5 V
± 0.2 V
V
CC
= 2.7 V
V
CC
= 3.3 V
± 0.3 V
UNIT
MIN MAX MIN MAX MIN MAX MIN MAX
f
clock
Clock frequency
‡
150 150 150 MHz
LE low
‡
3.3 3.3 3.3
t
w
Pulse duration
CLK high or low
‡
3.3 3.3 3.3
ns
Data before CLK↑
‡
1.4 1.7 1.5
t
su
Setup time
↑
CLK high
‡
1.2 1.6 1.3
ns
Data before LE
↑
CLK low
‡
1.4 1.5 1.2
Data after CLK↑
‡
0.9 0.9 0.9
t
h
Hold time
Data after LE↑
CLK
high or low
‡
1.1 1.1 1.1
ns
‡
This information was not available at the time of publication.