timing requirements over recommended operating free-air temperature range (unless otherwise
noted) (see Figures 1 through 3)
V
CC
= 1.8 V
V
CC
= 2.5 V
± 0.2 V
V
CC
= 2.7 V
V
CC
= 3.3 V
± 0.3 V
UNIT
MIN MAX MIN MAX MIN MAX MIN MAX
f
clock
Clock frequency
140 150 150 MHz
Pulse
LE high
3.3 3.3 3.3
t
w
duration
CLK high or low
3.3 3.3 3.3
ns
Data before CLK
2.3 2.4 2.1
CLK high
2 1.6 1.6
t
su
Setup time Data before LE
CLK low
1.3 1.2 1.1
ns
CLKEN before CLK
2 2 1.7
Data after CLK
0.7 0.7 0.8
CLK high
1.3 1.6 1.4
t
h
Hold time Data after LE
CLK low
1.7 2 1.7
ns
CLKEN after CLK
0.3 0.5 0.6
This information was not available at the time of publication.
switching characteristics over recommended operating free-air temperature range (unless
otherwise noted) (see Figures 1 through 3)
PARAMETER
FROM TO
V
CC
= 1.8 V
V
CC
= 2.5 V
± 0.2 V
V
CC
= 2.7 V
V
CC
= 3.3 V
± 0.3 V
UNIT
(INPUT) (OUTPUT)
MIN TYP MIN MAX MIN MAX MIN MAX
f
max
140 150 150 MHz
A B
1.3 4.8 5.2 1.6 4.5
B A
1 4.3 4.6 1 4.1
LEAB B
1 5.5 5.9 1.5 5.1
t
pd
LEBA A
1 5 5.3 1 4.7
ns
CLKAB B
1.5 6.1 6.3 1.6 5.5
CLKBA A
1.3 5.6 5.8 1.4 5
t
en
OEAB
B
1.6 6.1 6.7 1.6 5.7 ns
t
dis
OEAB
B
1.8 5.7 5.3 1.8 4.8 ns
t
en
OEBA
A
1.1 5.5 6.1 1.1 5.2 ns
t
dis
OEBA
A
1.3 5.2 4.8 1.6 4.4 ns
This information was not available at the time of publication.
operating characteristics, T
A
= 25°C
V
CC
= 1.8 V V
CC
= 2.5 V V
CC
= 3.3 V
PARAMETER TEST CONDITIONS
TYP TYP TYP
UNIT
Power dissipation
Outputs enabled
41 50
C
pd
capacitance
Outputs disabled
C
L
= 50 pF, f = 10 MHz
6 6
pF
This information was not available at the time of publication.