Datasheet
www.ti.com
ELECTRICAL CHARACTERISTICS
TIMING REQUIREMENTS
SN74ALVCH162374
16-BIT EDGE-TRIGGERED D-TYPE FLIP-FLOP
WITH 3-STATE OUTPUTS
SCES092F – JANUARY 1997 – REVISED OCTOBER 2004
over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER TEST CONDITIONS V
CC
MIN TYP
(1)
MAX UNIT
I
OH
= -100 µ A 1.65 V to 3.6 V V
CC
- 0.2
I
OH
= -2 mA 1.65 V 1.2
I
OH
= -4 mA 2.3 V 1.9
V
OH
2.3 V 1.7 V
I
OH
= -6 mA
3 V 2.4
I
OH
= -8 mA 2.7 V 2
I
OH
= -12 mA 3 V 2
I
OL
= 100 µ A 1.65 V to 3.6 V 0.2
I
OL
= 2 mA 1.65 V 0.45
I
OL
= 4 mA 2.3 V 0.4
V
OL
2.3 V 0.55 V
I
OL
= 6 mA
3 V 0.55
I
OL
= 8 mA 2.7 V 0.6
I
OL
= 12 mA 3 V 0.8
I
I
V
I
= V
CC
or GND 3.6 V ± 5 µ A
V
I
= 0.58 V 1.65 V 25
V
I
= 1.07 V 1.65 V -25
V
I
= 0.7 V 2.3 V 45
I
I(hold)
V
I
= 1.7 V 2.3 V -45 µ A
V
I
= 0.8 V 3 V 75
V
I
= 2 V 3 V -75
V
I
= 0 to 3.6 V
(2)
3.6 V ± 500
I
OZ
V
O
= V
CC
or GND 3.6 V ± 10 µ A
I
CC
V
I
= V
CC
or GND, I
O
= 0 3.6 V 40 µ A
∆ I
CC
One input at V
CC
- 0.6 V, Other inputs at V
CC
or GND 3 V to 3.6 V 750 µ A
Control inputs 3
C
i
V
I
= V
CC
or GND 3.3 V pF
Data inputs 6
C
o
Outputs V
O
= V
CC
or GND 3.3 V 7 pF
(1) All typical values are at V
CC
= 3.3 V, T
A
= 25 ° C.
(2) This is the bus-hold maximum dynamic current. It is the minimum overdrive current required to switch the input from one state to
another.
over recommended operating free-air temperature range (unless otherwise noted) (see Figure 1)
V
CC
= 2.5 V V
CC
= 3.3 V
V
CC
= 1.8 V V
CC
= 2.7 V
± 0.2 V ± 0.3 V
UNIT
MIN MAX MIN MAX MIN MAX MIN MAX
f
clock
Clock frequency
(1)
150 150 150 MHz
t
w
Pulse duration, CLK high or low
(1)
3.3 3.3 3.3 ns
t
su
Setup time, data before CLK ↑
(1)
2.1 2.2 1.9 ns
t
h
Hold time, data after CLK ↑
(1)
0.6 0.5 0.5 ns
(1) This information was not available at the time of publication.
5