Datasheet
www.ti.com
TIMING REQUIREMENTS
SWITCHING CHARACTERISTICS
SWITCHING CHARACTERISTICS
OPERATING CHARACTERISTICS
SN74ALVC162836
20-BIT UNIVERSAL BUS DRIVER
WITH 3-STATE OUTPUTS
SCES129E – MARCH 1998 – REVISED OCTOBER 2004
over recommended operating free-air temperature range (unless otherwise noted) (see Figure 1)
V
CC
= 2.5 V V
CC
= 3.3 V
V
CC
= 1.8 V V
CC
= 2.7 V
± 0.2 V ± 0.3 V
UNIT
MIN MAX MIN MAX MIN MAX MIN MAX
f
clock
Clock frequency
(1)
150 150 150 MHz
LE low
(1)
3.3 3.3 3.3
t
w
Pulse duration ns
CLK high or low
(1)
3.3 3.3 3.3
Data before CLK ↑
(1)
1.4 1.7 1.5
t
su
Setup time CLK high
(1)
1.2 1.6 1.3 ns
Data before LE↑
CLK low
(1)
1.4 1.5 1.2
Data after CLK ↑
(1)
0.9 0.9 0.9
t
h
Hold time ns
Data after LE↑ CLK high or low
(1)
1.1 1.1 1.1
(1) This information was not available at the time of publication.
over recommended operating free-air temperature range (unless otherwise noted) (see Figure 1)
V
CC
= 2.5 V V
CC
= 3.3 V
V
CC
= 1.8 V V
CC
= 2.7 V
FROM TO
± 0.2 V ± 0.3 V
PARAMETER UNIT
(INPUT) (OUTPUT)
MIN TYP MIN MAX MIN MAX MIN MAX
f
max
(1)
150 150 150 MHz
A
(1)
1 4.4 4.6 1.2 4
t
pd
LE Y
(1)
1.1 5.8 6.1 1.4 5.1 ns
CLK
(1)
1 5.2 5.5 1.1 5
t
en
OE Y
(1)
1.1 6.4 6.5 1.2 5.5 ns
t
dis
OE Y
(1)
1 4.7 5.2 1.7 5.1 ns
(1) This information was not available at the time of publication.
from 0 ° C to 65 ° C, C
L
= 50 pF
V
CC
= 3.3 V
FROM TO
± 0.15 V
PARAMETER UNIT
(INPUT) (OUTPUT)
MIN MAX
A 1 4
t
pd
Y ns
CLK 1.7 4.5
T
A
= 25 ° C
V
CC
= 1.8 V V
CC
= 2.5 V V
CC
= 3.3 V
PARAMETER TEST CONDITIONS UNIT
TYP TYP TYP
Outputs enabled
(1)
31 36
C
pd
Power dissipation capacitance C
L
= 0, f = 10 MHz pF
Outputs disabled
(1)
7 11
(1) This information was not available at the time of publication.
4