ELECTRICAL CHARACTERISTICS
SWITCHING CHARACTERISTICS
OPERATING CHARACTERISTICS
SN74ALVC126
QUADRUPLE BUS BUFFER GATE
WITH 3-STATE OUTPUTS
SCES111J JULY 1997 REVISED OCTOBER 2004
over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER TEST CONDITIONS V
CC
MIN TYP
(1)
MAX UNIT
I
OH
= -100 µ A 1.65 V to 3.6 V V
CC
- 0.2
I
OH
= -4 mA 1.65 V 1.2
I
OH
= -6 mA 2.3 V 2
V
OH
2.3 V 1.7 V
I
OH
= -12 mA 2.7 V 2.2
3 V 2.4
I
OH
= -24 mA 3 V 2
I
OL
= 100 µ A 1.65 V to 3.6 V 0.2
I
OL
= 4 mA 1.65 V 0.45
I
OL
= 6 mA 2.3 V 0.4
V
OL
V
2.3 V 0.7
I
OL
= 12 mA
2.7 V 0.4
I
OL
= 24 mA 3 V 0.55
I
I
V
I
= V
CC
or GND 3.6 V ± 5 µ A
I
OZ
V
O
= V
CC
or GND 3.6 V ± 10 µ A
I
CC
V
I
= V
CC
or GND, I
O
= 0 3.6 V 10 µ A
I
CC
One input at V
CC
- 0.6 V, Other inputs at V
CC
or GND 3 V to 3.6 V 750 µ A
Control inputs 3.5
C
i
V
I
= V
CC
or GND 3.3 V pF
Data inputs 3.5
C
o
Outputs V
O
= V
CC
or GND 3.3 V 5.5 pF
(1) All typical values are at V
CC
= 3.3 V, T
A
= 25 ° C.
over recommended operating free-air temperature range (unless otherwise noted) (see Figure 1)
V
CC
= 1.8 V V
CC
= 2.5 V V
CC
= 3.3 V
V
CC
= 2.7 V
FROM TO
± 0.15 V ± 0.2 V ± 0.3 V
PARAMETER UNIT
(INPUT) (OUTPUT)
MIN MAX MIN MAX MIN MAX MIN MAX
t
pd
A Y 1.3 5.6 1 3.4 3.4 1.1 3.1 ns
t
en
OE Y 1 5.9 1 3.8 3.8 1 3.3 ns
t
dis
OE Y 1.8 5.6 1 3.3 4.4 1 3.7 ns
T
A
= 25 ° C
V
CC
= 1.8 V V
CC
= 2.5 V V
CC
= 3.3 V
TEST
PARAMETER UNIT
CONDITIONS
TYP TYP TYP
Outputs enabled 15 17 19
Power dissipation
C
pd
C
L
= 0, f = 10 MHz pF
capacitance per gate
Outputs disabled 2 2 3
3