Datasheet
SN54ALS534A, SN74ALS534A, SN74AS534
OCTAL D-TYPE EDGE-TRIGGERED FLIP-FLOPS
WITH 3-STATE OUTPUTS
SDAS168B – APRIL 1982 – REVISED JULY 1996
3
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
†
Supply voltage, V
CC
7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage, V
I
7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Voltage applied to a disabled 3-state output 5.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
A
: SN54ALS534A –55°C to 125°C. . . . . . . . . . . . . . . . . . . . . . . . . . . .
SN74ALS534A 0°C to 70°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
–65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
SN54ALS534A SN74ALS534A
UNIT
MIN NOM MAX MIN NOM MAX
UNIT
V
CC
Supply voltage 4.5 5 5.5 4.5 5 5.5 V
V
IH
High-level input voltage 2 2 V
V
IL
Low-level input voltage 0.7 0.8 V
I
OH
High-level output current –1 –2.6 mA
I
OL
Low-level output current 12 24 mA
f
clock
Clock frequency 0 30 0 35 MHz
t
w
Pulse duration, CLK high or low 16.5 14 ns
t
su
Setup time, data before CLK↑ 10 10 ns
t
h
Hold time, data after CLK↑ 0 0 ns
T
A
Operating free-air temperature –55 125 0 70 °C
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
SN54ALS534A SN74ALS534A
UNIT
PARAMETER
TEST
CONDITIONS
MIN TYP
‡
MAX MIN TYP
‡
MAX
UNIT
V
IK
V
CC
= 4.5 V, I
I
= –18 mA –1.5 –1.5 V
V
CC
= 4.5 V to 5.5 V, I
OH
= –0.4 mA V
CC
–2 V
CC
–2
V
OH
V
CC
=45V
I
OH
= –1 mA 2.4 3.3
V
V
CC
=
4
.
5
V
I
OH
= –2.6 mA 2.4 3.2
V
OL
V
CC
=45V
I
OL
= 12 mA 0.25 0.4 0.25 0.4
V
V
OL
V
CC
=
4
.
5
V
I
OL
= 24 mA 0.35 0.5
V
I
OZH
V
CC
= 5.5 V, V
O
= 2.7 V 20 20 µA
I
OZL
V
CC
= 5.5 V, V
O
= 0.4 V –20 –20 µA
I
I
V
CC
= 5.5 V, V
I
= 7 V 0.1 0.1 mA
I
IH
V
CC
= 5.5 V, V
I
= 2.7 V 20 20 µA
I
IL
CLK, OE
V
CC
=55V
V
I
=04V
–0.1 –0.1
mA
I
IL
D
V
CC
=
5
.
5
V
,
V
I
=
0
.
4
V
–0.2 –0.2
mA
I
O
§
V
CC
= 5.5 V, V
O
= 2.25 V –20 –112 –30 –112 mA
Outputs high 11 19 11 19
I
CC
V
CC
= 5.5 V
Outputs low 19 28 19 28
mA
Outputs disabled 10 31 20 31
‡
All typical values are at V
CC
= 5 V, T
A
= 25°C.
§
The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, I
OS
.